Messages and Troubleshooting
8-2 7612-A2-GB20-10
November 1997
Device Messages

The Device Messages in Table 8-1, listed in alphabetical order, may appear in the

messages area at the bottom of the ATI screens.

Table 8-1. Device Messages (1 of 2)

Device Message What Message Indicates What To Do

Blank Entries
Removed New had been selected
from the Administer Logins
screen, no entry was made,
and Save was selected.
No action needed.
Reenter the Login ID,
Password, and Access Level.
Cannot Save – No
Login IDs with Access
Level 1
An attempt was made to
save logins with Access
Levels 2 and 3 only.
Create a Login with Access
Level 1.
Command Complete Action requested has
successfully completed. No action needed.
Invalid Character (
x
)1An invalid ASCII character
has been entered. Reenter information using valid
characters.
Invalid – Network
Initiated CSU (or DSU)
Loopback Active
Network-initiated loopback
was in progress when
another selection was
made.
No action needed.
Invalid Password Login is required and an
incorrect password was
entered; access is denied.
Try again.
Contact your system
administrator to verify your
password.
Invalid – [Test]
Already Active [Test] can be a CSU, DSU,
or DTE Local Loopback, or
a Send 511 or Monitor 511.
The [test] was already in
progress when another
selection was made.
Allow test to continue.
Select another test.
Stop the test.
Invalid Test
Combination A loopback or 511 pattern
test was in progress when
Start was selected to start
another test, or was active
on the same or another
interface when Start was
selected.
Wait until other test ends and
message clears.
Abort all tests from the Test
menu screen.
Stop the test from the same
screen the test was started
from.
Limit of six Login IDs
reached An attempt to enter a new
login ID was made, and the
limit of six login/password
combinations has been
reached.
1. Delete another login/password
combination.
2. Reenter the new login ID.
1
x
is the character not being accepted.