Testing

7-5

7612-A2-GB20-10 November 1997
Data Port Tests
To access the Data Port Tests screen, follow this menu selection sequence:
Main Menu
Test
Data Port Tests
main/test/port
Device Name:Node A Model: 7612
DATA PORT TESTS
Test Command Status Result
Local Loopback: Start Inactive 000:00:00
Send 511: Start Inactive 000:00:00
Monitor 511: Stop Active 255:59:59+ - Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu MainMenu Exit
ResetMon

Local Loopback

Local Loopback loops the user data back to the DTE. This loopback is located as
closely as possible to the User Data Port (DTE) interface.
DSU CSU
DTE
Interface Aggregate DDS
Network
Port
97-15344
DTE
Port
Local Loopback

511 Test Pattern for the DTE

This test sends and monitors a 511 test pattern over the User Data Port interface.
The 511 monitor expects the external equipment to provide the clock for the
511 pattern on the interchange circuit CT113 – Transmit Signal Element Timing –
DTE Source (XTXC or TT) for timing the incoming pattern. Refer to
DTE Port (V.35) Connector
in Appendix E,
Cables and Pin Assignments
.