Messages and Troubleshooting

Table 8-1. Device Messages (2 of 2)

Device Message

What Message Indicates

What To Do

 

 

 

No Security Records

Delete was selected from

H No action needed.

to Delete

the Administer Login

H Enter a security record.

 

screen, and no security

 

 

 

records had been defined.

 

 

 

 

Password Matching

Password entered in the

H Try again.

Error ± Re-enter

Re-enter Password field of

H Contact your system

Password

the Administer Logins

administrator to verify your

 

screen does not match

 

password.

 

what was entered in the

 

 

 

Password field.

 

 

 

 

Please Wait

Command takes longer

Wait until message clears.

 

than 5 seconds.

 

 

 

 

Test Active

A test is running and no

H Contact service provider if test

 

higher priority health and

was initiated by the network.

 

status messages exist.

H Wait until the other test ends

 

 

 

 

and message clears.

 

 

H Cancel all tests from the Test

 

 

screen.

 

 

H Stop the test from the same

 

 

screen the test was started

 

 

from.

 

 

 

Troubleshooting

This DSU is designed to provide you with many years of trouble-free service. If a problem occurs, however, refer to Table 8-2 for possible solutions.

Table 8-2. Troubleshooting (1 of 2)

Symptom

Possible Cause

Solutions

 

 

 

Alarm LED is on.

One of several alarm

Refer to Table 6-1,Health and

 

conditions exists. Health

Status Messages, for

 

and Status displays the

recommended action.

 

alarm condition.

 

 

 

 

Cannot access the

Login or password is

H Power the DSU off and on and

DSU via the ATI.

incorrect, Terminal port is

try again.

 

misconfigured, or the DSU

H If problem recurs, try to access

 

otherwise configured so it

 

the ATI through a Telnet session.

 

prevents access.

 

 

 

 

H Reload Factory Defaults. Refer

 

 

to Device Reset in Chapter 7.

 

 

H Do a Device Reset. Refer to

 

 

Device Reset in Chapter 7.

 

 

 

7612-A2-GB20-10

November 1997

8-3

Page 63
Image 63
Paradyne 7612 SNMP DSU manual Troubleshooting, Device Messages 2 What Message Indicates What To Do

7612 SNMP DSU specifications

The Paradyne 7612 SNMP DSU (Data Service Unit) is a robust and versatile device designed for effective communication in data networks. This device is particularly suited for businesses that require reliable connectivity to support their operations. The 7612 integrates advanced technologies that enhance performance, scalability, and ease of management.

One of the main features of the Paradyne 7612 is its support for SNMP (Simple Network Management Protocol), which allows for comprehensive monitoring and management of network devices. This capability ensures that network administrators can easily track performance metrics and troubleshoot issues in real time, thereby minimizing downtime and enhancing overall operational efficiency.

The 7612 also provides multiple interface options, including T1/E1 and fractional T1, enabling users to select the most suitable bandwidth for their specific requirements. With full duplex capabilities, the device can handle simultaneous data transmission and reception, ensuring efficient communication and high throughput.

In terms of security, the Paradyne 7612 incorporates features such as port security and access control lists (ACLs). These measures protect the network from unauthorized access, ensuring that sensitive data remains secure during transmission. Additionally, the DSU incorporates intelligent diagnostic features, such as loopback testing and error monitoring, enabling proactive identification and resolution of network issues.

The device is built with a modular design, allowing for easy upgrades and scalability as business needs grow. This flexibility ensures that organizations can adapt their network infrastructure without the need for significant overhauls or extensive downtime.

The Paradyne 7612 also boasts an intuitive web-based user interface, simplifying configuration and management tasks. Network administrators can access settings and monitor performance from any location, streamlining network management processes.

With a focus on reliability, the 7612 is designed to operate in various environmental conditions, offering features such as extended temperature ranges and robust construction, making it suitable for deployment in both indoor and outdoor settings.

In summary, the Paradyne 7612 SNMP DSU stands out in the realm of data communication devices with its advanced SNMP capabilities, versatile interface options, robust security features, modular design, and user-friendly management interface. These characteristics make it an ideal solution for enterprises seeking to maintain reliable, scalable, and secure data communication networks.