Configuration Option Tables

SNMP Traps Options

For SNMP Traps Options, refer to Table A-9. To access the SNMP Traps Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From Edit

SNMP SNMP Traps

Table A-9. SNMP Traps Options (1 of 2)

SNMP Traps

Possible Settings: Enable, Disable

Default Setting: Disable

Controls the generation of SNMP trap messages. The options for addresses and types of traps are located in this table.

HSNMP Management must be enabled. See Table A-7.

Enable ± SNMP trap messages are sent out to SNMP managers.

Disable ± No SNMP trap messages are sent out.

Number of Trap Managers

Possible Settings: 1, 2, 3, 4, 5, 6

Default Setting: 1

Sets the number of SNMP management systems that will receive SNMP traps.

1 to 6 ± Number of trap managers. An NMS IP address is required for each manager.

Trap Manager n IP Address

Possible Settings: 000.000.000.000 ± 223.255.255.255, Clear

Default Setting: 000.000.000.000

Specifies the IP address used to identify each SNMP trap manager. n represents the number of the manager (from 1 to 6).

000.000.000.000 ± 223.255.255.255 ± Enter an address for each SNMP trap manager. The range for the first byte is 000 to 223, with the exception of 127. The range for the remaining three bytes is 000 to 255.

Clear ± Clears the IP address and sets to all zeros.

Trap Manager n Destination

Possible Settings: None, Ethernet, IMC

Default Setting: None

Provides the network destination path of each trap manager. n is the number of the manager (from 1 to 6).

None ± No destination is specified for Trap Manager n.

Ethernet ± Ethernet port is the network destination.

HPort Use option must not be set to Disable. See Table A-4.

IMC ± The In-Band Management Channel is the default network destination.

HIn-Band Management Channel Rate (bps) option must be set to 1600, 4000, or 8000 bps. See Table A-2.

7612-A2-GB20-10

November 1997

A-17

Page 81
Image 81
Paradyne 7612 SNMP DSU manual Table A-9. Snmp Traps Options 1, Number of Trap Managers, Trap Manager n Destination

7612 SNMP DSU specifications

The Paradyne 7612 SNMP DSU (Data Service Unit) is a robust and versatile device designed for effective communication in data networks. This device is particularly suited for businesses that require reliable connectivity to support their operations. The 7612 integrates advanced technologies that enhance performance, scalability, and ease of management.

One of the main features of the Paradyne 7612 is its support for SNMP (Simple Network Management Protocol), which allows for comprehensive monitoring and management of network devices. This capability ensures that network administrators can easily track performance metrics and troubleshoot issues in real time, thereby minimizing downtime and enhancing overall operational efficiency.

The 7612 also provides multiple interface options, including T1/E1 and fractional T1, enabling users to select the most suitable bandwidth for their specific requirements. With full duplex capabilities, the device can handle simultaneous data transmission and reception, ensuring efficient communication and high throughput.

In terms of security, the Paradyne 7612 incorporates features such as port security and access control lists (ACLs). These measures protect the network from unauthorized access, ensuring that sensitive data remains secure during transmission. Additionally, the DSU incorporates intelligent diagnostic features, such as loopback testing and error monitoring, enabling proactive identification and resolution of network issues.

The device is built with a modular design, allowing for easy upgrades and scalability as business needs grow. This flexibility ensures that organizations can adapt their network infrastructure without the need for significant overhauls or extensive downtime.

The Paradyne 7612 also boasts an intuitive web-based user interface, simplifying configuration and management tasks. Network administrators can access settings and monitor performance from any location, streamlining network management processes.

With a focus on reliability, the 7612 is designed to operate in various environmental conditions, offering features such as extended temperature ranges and robust construction, making it suitable for deployment in both indoor and outdoor settings.

In summary, the Paradyne 7612 SNMP DSU stands out in the realm of data communication devices with its advanced SNMP capabilities, versatile interface options, robust security features, modular design, and user-friendly management interface. These characteristics make it an ideal solution for enterprises seeking to maintain reliable, scalable, and secure data communication networks.