Digital Access Keypad Manual
INSTALLER PROGRAMMING
These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.
Enter Programming Mode |
|
| (DEFAULT: 0 0 0 0 ) | ||||
Enter Master code |
| Confirm | Func ion | ||||
X X X X * |
|
| * |
| Enter into programming mode | ||
*Key in the Master Code. |
| ||||||
|
|
| |||||
Note: For | 0 0 0 0 | ||||||
|
|
|
|
| |||
Data Refresh |
|
|
|
| |||
Op ion |
| Confirm | Function |
|
| ||
8 | 9 0 | 1 | # | Clears all previously stored data. | |||
|
|
|
| ||||
Configure Relay Outputs |
|
| (DEFAULT: Momentary, | ||||
Option | Output ime |
| Confirm | Function | |||
4 | 0 | 1 to 999 |
|
| # | Relay #1, momentary mode, from 1 to 999 seconds | |
4 | 1 |
|
|
|
| # | Relay #1, shunt mode (ON/OFF) |
5 | 0 | 1 to 999 |
|
| # | Relay #2, momentary mode, from 1 to 999 seconds | |
5 | 1 |
|
|
|
| # | Relay #2, shunt mode (ON/OFF) |
6 | 0 | 1 to 999 |
|
| # | Output #3, momentary mode, from 1 to 999 seconds | |
6 | 1 |
|
|
|
| # | Output #3, shunt mode (ON/OFF) |
|
|
|
|
| |||
Wrong Code Lockout |
|
|
| (DEFAULT: 10 tries / 30 seconds) | |||
Option | # of tries | Confirm | Function | ||||
7 | 0 |
|
|
|
| After 10 successive wrong codes, | |
7 | 1 | 5 to 10 |
|
| After 10 successive wrong codes, Duress activated | ||
7 | 2 |
| # | After 5 to 10 wrong codes, | |||
7 | 6 0 | 0 |
|
| # | None of the above | |
|
|
|
| ||||
Door |
|
| (DEFAULT: Disabled) | ||||
Op ion | Code entry | Confirm | Function | ||||
8 | 0 | { | 1 |
| # | Door | |
0 |
| # | Door | ||||
|
|
| |||||
Output Activation Announcer |
| (DEFAULT: On) | |||||
Option | Code entry | Confirm | Function | ||||
8 | 1 | { | 1 |
| # | ||
0 |
| # | The beep is disabled, replaced by 2 short beeps for valid user codes. | ||||
|
|
| |||||
|
|
|
|
| |||
User Code Entry Mode |
|
|
| (DEFAULT: Manual) | |||
Op ion | Code entry | Confirm | Function | ||||
|
| { | 1 |
| # | Auto Entry Mode is selected. The # key that follows he user code is NOT required in | |
8 | 2 |
|
|
| code entry. The User Codes MUST be set to he same digit length as he Master Code. | ||
0 |
|
| Manual Entry Mode is selected. The # key that follows the user code is required in | ||||
|
|
| # | ||||
|
|
|
| code entry. The User Codes can be | |||
Keypress Beeps |
|
|
| (DEFAULT: On) | |||
Op ion | Code entry | Confirm | Function | ||||
8 | 3 | { | 1 |
| # | Keypad beeps when a key is pressed. | |
0 |
| # | Silent operation | ||||
|
|
| |||||
LED Flashes in Standby Mode |
| (DEFAULT: On) | |||||
|
| Code entry | Confirm | Function | |||
8 | 4 | { | 1 |
| # | Amber LED ON during standby mode. | |
0 |
| # | Amber LED OFF during standby mode. | ||||
|
|
| |||||
Door Propped Open Alarm Timer |
| (DEFAULT: Off) | |||||
Op ion | Code entry | Confirm | Function | ||||
9 |
| { | 0 |
| # | No door propped open alarm | |
|
| 1 to 999 |
| # | Allowable time from 1 to 999 seconds that the door can be left open before the alarm starts. |
Exit Programming Mode
Confirm Function
*Exits programming mode, returns keypad to normal operations
Digital Access Keypad Manual
UNIQUE FEATURES
•
•Mantrap
•Relay output #1 inhibit control
•Door forced open warning
•Door propped open warning
•Auto or manual code entry checking:
o Auto code entry checking mode
o Manual code entry checking mode
•Keypad active output
•Alarm output
•Door auto relock
•Duress output
•Backlit keypad
Page 14 | |
Page 3 |