SECO-LARM USA SK-1131-SQ Digital Access Keypad Manual, is not required for AC-poweredlocks

Models: SK-1131-SQ

1 8
Download 8 pages 11.72 Kb
Page 6
Image 6
is not required for AC-powered locks.

Digital Access Keypad Manual

WIRING:

Example Wiring, with Inhibit Control Authorized

Digital Access Keypad Manual

WIRING:

Auxiliary Accessories

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT 1

 

EG

 

(+) (--) Door

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.C. C. N.O

 

IN

 

12~24V AC DC Sens

 

 

(--)

(+)

( -)

(+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(+)

GREENLED

GREENLED

REDLED

REDLED

OUTPUT3

O/PDisable1

 

N.C.

N.O.

 

 

 

 

 

OR

 

 

 

 

 

 

REMARKS:

 

 

 

 

TAMPER N.C.

WIRE HARNESS

(1) RED

(2) BLACK

(3)

(4)

(5)

(6)

(7)

ALARM

CONTROL

PANEL

24-hour N.C.

protection

zone

 

Electric

+

--

Output relay #1

 

12VDC

 

 

+ Lock --

 

N.O. output for fail-secure lock.

 

power

 

N.C. output for fail-safe lock.

 

 

supply

 

LEDs:

 

 

 

 

 

(for DC

 

 

Each LED requires a 1.5K-Ohm

Diode

 

 

series resistor for 24V operation.

use only)

 

 

 

1N4004

 

 

 

 

Cathode

 

 

 

Additional egress buttons

Egress button (inside the

 

 

N.O.

N.O.

can be connected in

protected premises)

 

 

parallel as needed

 

 

 

 

DURESS OUTPUT

WIRE HARNESS

(10)

 

ALARM

(11)

 

CONTROL

(12)

 

PANEL

(13)

 

 

(14)

 

24-hour N.O.

(15)

LIGHT GREEN

protection zone,

(16)

WHITE/ORANGE

 

 

max. 100mA

Note:

Connect a 1N4004 diode as close as possible to and in parallel with the DC-

 

powered electromagnetic or electric lock. This absorbs possible electromagnetic

 

interference to prevent operation of the lock from damaging the keypad. A 1N4004

 

is not required for AC-powered locks.

Connect the ground (-) terminal of the keypad to earth to prevent electrostatic

DOOR SENSING

 

DOOR

SENS

 

(--)

GND

 

 

 

 

 

 

MAGNETIC

DOOR

CONTACT

(N.C.)

Required for:

Door Auto Relock

Door Forced-open Alarm

Door Propped-up Alarm

Mantrap (Interlock) Control

 

discharge from damaging the keypad.

The connection of relay output #1 disable to output #3 as shown above is optional.

 

When so wired, output #3 is the inhibit control. To use, program output #3 for shunt

 

on/off operation. When output #3 is ON, relay output #1 will not work. For example,

 

this can be used to prevent users from entering the protected premises during the

 

evening or weekend. See programming option 61.

As wired, the green LED lights while relay output #1 is activated to activate the

 

lock.

As wired, the red LED lights to show that relay output #1 is disabled by the

 

activation of output #3.

Tape all unused wires to prevent short circuits.

KEY ACTIVE or ALARM OUTPUT

 

12V

 

 

 

12V

(3)

 

Low

(3)

 

 

(4)

1.5k

(4)

 

 

power

 

 

(5)

 

(5)

 

 

 

piezo

 

 

(6)

LED

(6)

 

 

buzzer

 

 

(7)

(7)

 

 

PINK

 

PINK

 

(8)

 

(8)

Isolation

(9)

 

 

(9)

 

 

 

 

relay

 

 

 

 

 

OR

(See page 15 for jumper selection)

N.O. relay contact

The Key Active Output will switch to ground (- ) for 10 seconds whenever a key is touched. Use to turn ON an LED and/or a small buzzer to notify a guard, or to energize a relay to switch ON lights or CCTV camera.

Only one connection option is recommended. Make sure the current does not exceed the maximum rating of 100mA.

An external power supply and isolation relay are necessary to drive high power devices such as lights or CCTV cameras.

WARNING:

RELAY OUTPUT #2 --Example, to shunt an alarm N.C. zone

If the inhibit control is used, all personnel must exit the protected premises before output #3 is activated. Otherwise, personnel in the protected premises will not be able to exit until output #3 is turned OFF.

The user code for output #3 in this case should be given only to personnel authorized to enter the premises any time. It should not be given to other users.

WIRE HARNESS

(8)

(9) WHITE/BROWN

(10) BLUE

(11)

(12)

Wire

Harness

WIRE HARNESS

N.C.

N.C. magnetic contact

To protection zone of an alarm control panel

Use Normally Open (N.O.) output contact to shunt a Normally Closed (N.C.) protection zone of an alarm system.

Set relay output #2 to Start / Stop mode (programming option 51)

Page 6

SECO-LARM U.S.A., Inc.

Page 11

Page 6
Image 6
SECO-LARM USA SK-1131-SQ warranty Digital Access Keypad Manual, is not required for AC-poweredlocks, SECO-LARMU.S.A., Inc