TABLE 14 b
PROBLEMS | CAUSE | COUNTERMEASURES |
|
|
|
Sound is not | Sound volume adjustment is not | Adjust the SWITCH UNIT's sound adjustment volume |
emitted. | correct. | control. (See Service Manual) |
|
|
|
| Malfunctioning BD. and Amp. | Perform SOUND TEST. (See Service Manual) |
|
|
|
When the | The power is not ON. | Firmly insert the plug into the outlet. |
power SW of |
|
|
the satellite is | Incorrect power source/voltage. | Make sure that the power supply/voltage are correct. |
turned ON, the |
|
|
satellite is not |
|
|
activated. |
|
|
|
|
|
Printing on |
|
|
cards is too | The card reader/writer head is dirty. | Perform head cleaning. (See Service Manual) |
light. |
|
|
|
|
|
Fluorescent |
|
|
lamp doesn't | Fluorescent lamp need replacement. | Replace the fluorescent lamp. (See Section 12) |
light up. |
|
|
|
|
|
Lamp doesn't |
|
|
light up. | Lamp need replacement. | Replace the lamp. (See Section 12) |
|
|
|
FUSE REPLACEMENT
●In case fuse replacements other than those stated in this manual are necessary, con- tact where you purchased the product from for inquiries regarding this matter.
WARNING! | ● Fuse replacements other than those specified can cause accidents and are strictly |
forbidden. |
●In order to prevent an electric shock, be sure to turn power off and unplug from the socket outlet before performing work by touching the internal parts of the product.
●Be careful so as not to damage wirings. Damaged wiring can cause electric shock and short circuit accidents.
●Be sure to use fuses meeting specified rating. Using fuses exceeding the specified rating can cause fire and electric shock accidents.
●After eliminating the cause of the blowing of fuse, replace the fuse. Depending on the cause of fuse blowing, continued use with the fuse as is blown can cause genera- tion of heat and fire hazard.
Fuse 250V 10A
43 | www.seuservice.com |