26

Error checklist

 

Error

 

Possible cause

Receiver does not work;

 

display panel dark

Fuse defective

Receiver does not work;

 

display panel lit up

Transmission frequency does not agree

 

 

with receiving frequency

 

 

Squelch threshold adjusted too high

Sound distorted

AF output signal adjusted too high. Input

 

 

of the connected mixing console or

 

 

amplifier is overmodulated

 

 

Transmission microphone overmodulated,

 

 

reduce microphone sensitivity

 

 

(see corresponding section in the operating

 

 

manual of the transmitter)

Sound overlaid with background noise

Transmitter not sensitive enough; where

 

 

appropriate, switch transmitter sensitivity

from “low” to “high” or increase trans- mitter sensitivity from - 30 dB to 0 dB via operating menu (SKM 3072-U only)

27 Safety instructions

Never open electronic devices! This must only be done by authorised personnel and is all the more important for current-carrying units. If devices are opened by customers in breach of this instruction, the warranty becomes null and void.

Always disconnect the receiver from the mains by removing the plug when you wish to change connections or move the device to a different place.

Keep the receiver away from central heating radiators and electric heaters. Never expose it to direct sunlight.

Use the receiver in dry rooms only.

Use a damp cloth for cleaning the receiver. Do not use any cleansing agents or solvents.