Putting the SR 2020 D into operation

Rack-mounting

CAUTION! Risks when rack mounting the transmitter!

When installing the device in a closed or multi-rack assembly, please consider that, during operation, the ambient temperature, the mechanical loading and the electrical potentials will be different from those of devices which are not mounted into a rack:

The ambient temperature within the rack must not exceed the temperature limit specified in the specifications.

When installing the device in a rack, take good care not to affect the ventilation required for safe operation. If necessary, provide additional ventilation.

Make sure the mechanical loading of the rack is even to avoid a hazardous condition such as a severely unbalanced rack.

When connecting the device to the mains, observe the information indicated on the type plate. Avoid circuit overloading. If necessary, provide overcurrent protection.

When installing the device in a closed or multi- rack assembly, please note that intrinsically harmless leakage currents of the individual mains units may accumulate, thereby exceeding the allowable limit value. As a remedy, ground the rack via an additional ground connection.

Mounting the antennas For the best possible radiation power, you should align the to the front or rear antennas vertically. If this is not possible, use one of the optional of the rack antenna mounts (see “Accessories and spare parts” on

page 25):

You mount...

Antenna mount

... 1 transmitter

AM 2

 

 

... 2 transmitters

GA 3030 AM

 

 