If a problem occurs....

Problem

Possible cause

Possible remedy

No operation

No mains connection

Check the mains unit and the connection to

indication on the

 

the DC IN socket (see page 12)

transmitter

 

 

Audio signal is

Transmitter sensitivity is

Change the sensitivity of the microphone

distorted

adjusted too high

input or line input (see page 19)

 

 

Select the source of the input signal

 

 

(see page 19)

Occasional drop outs

Distance to the transmitter is

Reduce the distance to the transmitter

in the audio signal

too great

 

 

Interference of unknown origin

Set the transmitter and receiver to a

 

 

different channel (see page 17)

 

Interference is being received

Change the transmitters to different

 

from a second transmitter

channels (see page 17)

No radio waves on the

Antenna is badly positioned

Improve the position of the transmitting

receiver display

 

antenna

 

 

Mount the antenna to the front of the rack

 

No RF signal:

Set the transmitter and receiver to the same

 

transmitter and receiver are

channel (see page 17)

 

not on the same channel

 

 

No RF signal:

Reduce the distance between receiver and

 

transmission range is

transmitter

 

exceeded

Improve the position of the transmitting

 

 

antenna

 

 

 

If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed solutions, please contact your local Sennheiser agent for assistance.