Installation

Installation

Place machine in a convenient location providing ample support, drainage and room for maintenance.

Remove bolts from pallet to foot bracket. Install rubber feet provided as shown in exploded view.

Location:

The location should protect the machine from damag- ing environmental conditions, such as; wind, rain, and freezing.

1.This machine should be run on a level surface where it is not readily influenced by outside sourc- es such as strong winds, freezing temperatures, rain, etc. It should be located to allow accessibility for refilling of fuel, adjustments and maintenance. Normal precautions should be taken by the op- erator of the machine to prevent moisture from reaching the electrical controls.

2.It is recommended that a partition be made be- tween the wash area and the machine to prevent water spray from coming in contact with the machine. Excess moisture reaching any electric components or electrical controls will reduce ma- chine life and may cause electrical shorts.

3.During installation of the machine, beware of poorly ventilated locations or areas where exhaust fans may cause an insufficient supply of oxygen. Sufficient combustion can only be obtained when there is a sufficient supply of oxygen available for the amount of fuel being burned. If it is necessary to install a machine in a poorly ventilated area, out- side fresh air may have to be piped to the burner and a fan installed to bring air into the machine.

Electrical:

This machine, when installed, must be electrically grounded in accordance to local codes. Check for proper power supply using a volt meter.

Placement:

Do not locate near any combustible material. Keep all flammable material at least 20 feet away.

Allow enough space for servicing the machine.

Local code will require certain distances from floor and walls. (Two feet away from walls should be ad- equate.)

Water Source:

The water source for the pressure washer should be supplied by a minimum 5/8” I.D. garden hose with a city water pressure of not less than 30 PSI. If the water supply is inadequate, or if the garden hose is kinked, the attached pressure washer will run very rough and the burner will not fire.

Connection:

See Component Identification.

Venting:

Adding exhaust vent pipe to your oil fired burner is not recommended because restricted air flow causes carbon build-up, which affects the operation, and in- creases maintenance on the coil. If a stack must be used, refrain from using 90° bends. If the pipe can not go straight up then use only 45° bends and go to the next size pipe.The overall pipe length must not exceed 6 feet in length. The burner air adjustment must be performed after vent pipe is installed. Use a smoke tester for proper air setting.