Caution: Be sure to turn the ON/OFF switch to the "OFF" position and disconnect

Cleaning the agitator assembly

1
2
3
CLEARING BLOCKAGES AND CLEANING THE AGITATOR ASSEMBLY
the power cord from the wall outlet before clearing any blockages in the
suction hose and cleaning the agitator assembly.

Cleaning blockages

Remove the bottom plate(refer to page 14)
Remove any blockages from the nozzle head.
Reattach the bottom plate to the nozzle head, and then operate the vacuum cleaner
to check that the blockage has been properly cleared. If the nozzle head is still blocked,
the suction force will be weak.

Cleaning blockages in the nozzle head

When threads get caught in the agitator assembly, clean the assembly.
Remove threads caught in the assembly by cutting them
with scissors.
11
Remove the bottom plate(refter to page 14)
Set the vacuum cleaner to the upright position.
Remove the hosecuff from the suction inlet and
then remove any blockages from the hose.
Reattach the hose cuff to the suctioninlet,and
then operatethe vacuum cleaner to checkthat
the blockage has been properly cleared.If the hose
is still blocked,the suction force will be weak.
1
2
3
Scissors
Threads
Nozzle Head
Hose Cuff
Suction Inlet
Suction Hose A

Cleaning blockages in the suction hose A, B

When the suction hose A, B or Nozzle head is
blocked, the bypass valve will be opened
automatically to protect the motor, resulting
in the suction force being reduced. The bypass
valve will be at its original position automatically
after the blockage is removed.
Caution: Bypass Valve
(Inside)