STATUS INDICATORS

When the following indicators light up or blink on the operation panel or the following alphanumeric codes appear in the display, solve the problem immediately referring to both the table below and the relevant page.

Be sure to use only genuine SHARP parts and supplies.

 

Indication

 

Cause and remedy

Page

 

 

Steadily

Replacement of drum cartridge will be needed

70

 

Drum replacement

lit

soon. Prepare a new cartridge.

 

 

 

required indicator

Blinking

Drum cartridge must be replaced. Replace it with

58

 

 

a new one.

 

TD cartridge

Steadily

Replacement of TD cartridge will be needed

70

 

lit

soon. Prepare a new cartridge.

 

replacement

 

 

 

TD cartridge must be replaced. Replace it with a

 

 

required indicator

Blinking

57

 

new one.

 

 

 

 

 

 

 

 

 

 

A misfeed has occurred. Remove the misfed

 

 

Misfeed indicator

Blinking

paper referring to the description of "MISFEED

63

 

 

 

REMOVAL".

 

 

SPF misfeed

 

An original misfeed has occurred in the SPF.

 

 

Blinking

Remove the misfed originals referring to the

67

 

indicator

 

 

description of "D: Misfeed in the SPF".

 

 

 

 

 

 

 

 

 

 

 

 

 

The unit is in the preheat mode. Press any key to

54

 

 

 

cancel the preheat mode.

 

Power save indicator is

 

 

The unit is in the auto power shut-off mode.

 

 

steadily lit.

 

 

 

 

Press the start ( ) key to cancel the auto power

54

 

 

 

 

 

 

shut-off mode.

 

 

 

 

 

 

The paper tray indicator is

The paper tray is not installed properly. Push the

 

blinking.

 

tray into the unit securely.

 

 

 

 

 

 

 

 

"CH" is blinking in the

The TD cartridge is not installed. Check if the

57

 

display.

 

cartridge is installed.

 

 

 

 

"CH" is steadily lit in the

Side cover is open. Close the side cover

 

 

securely by pressing the round projections near

 

display.

 

 

 

the side cover open button.

 

 

 

 

 

 

 

 

 

 

 

 

 

The paper tray or multi-bypass tray is empty.

15, 17

 

 

 

Load paper.

 

"P" is blinking in the display.

 

 

A misfeed has occurred in the paper tray or

63

 

 

 

 

 

 

multi-bypass tray. Remove the misfed paper.

 

 

 

 

 

A letter and a number appear

The scan head locking switch is locked. Unlock

9

 

alternately.

 

the scan head locking switch.

 

 

 

 

 

 

 

 

 

 

 

The unit will not function. Turn the power switch

 

 

A letter and a number appear

off, remove the power cord from the outlet, and

 

alternately.

 

contact our Technical Assistance Department at

 

 

1-(630)378-3590 in the USA or 905-568-7140 in

 

 

 

 

 

 

 

 

Canada.

 

62