MATERIAL SAFETY DATA SHEET

 

Page : 3/4

 

 

 

 

Date Issued

: Nov. 1, 2007

 

 

 

 

MSDS No. F-01601

Exposure Limit Values

 

 

 

 

OSHA-PEL(USA)

 

: 15mg/m3 (Total Dust),

5mg/m3 (Respirable Dust)

 

ACGIH-TLV(USA)

 

: 10mg/m3 (Total Dust),

3mg/m3 (Respirable Dust)

 

Personal Protective Equipment

 

 

 

 

Respiratory Protection

: Not required under intended use.

 

 

Hand Protection

 

: Not required under intended use.

 

 

Eye Protection

 

: Not required under intended use.

 

 

Skin Protection

 

: Not required under intended use.

 

 

Other Protective Equipment

: Use of a dust mask and goggles are recommended when handling a large

 

 

quantity of toner or during long term exposure, as with any non-toxic dust.

 

 

 

 

9.PHYSICAL AND CHEMICAL PROPERTIES

 

 

 

 

 

 

 

 

 

Appearance

 

 

 

 

 

Physical State : Solid

Form : Powder

Color : Black

Odor : odorless

 

Ph

 

: Not applicable

 

 

 

Boiling / Melting Point

: Not applicable

 

 

 

Softening Point(°C)

: 100 - 130

 

 

 

Flash Point(°C)

 

: Not applicable

 

 

 

lgnition Point(°C )

 

: > 350

 

 

 

Explosion Properties

: No data

 

 

 

Density(g/cm³)

 

: 1.1 (bulk density : 0.35)

 

 

Solubility in Water

 

: Negligible

 

 

 

 

 

 

 

 

10.STABILITY AND REACTIVITY

 

 

 

 

 

 

 

 

 

 

Stability

 

: Stable

 

 

 

Hazardous Reactions

: Dust explosion, like most finely divided organic powders.

 

Conditions to Avoid

: Electric discharge, throwing into fire.

 

 

Materials to Avoid

 

: Oxidizing Materials

 

 

 

Hazardous Decomposition Products : CO, CO2 and NOX

 

 

 

Further Information

: None

 

 

 

 

 

 

 

11.TOXICOLOGICAL INFORMATION

 

 

 

Acute Toxicity

 

 

 

 

 

Ingestion(oral)

: LD50 > 2500mg/kg [Estimated from the other product containing similar material]

Inhalation

: No data

 

 

 

 

Eye irritation

: Not an irritant [Estimated from the other product containing similar material]

 

Skin irritation

: Not an irritant [Estimated from the other product containing similar material]

 

Skin sensitizer

: No sensitized [Estimated from the other product containing similar material]

 

Mutagenicity

: Negative (Ames Test) [Estimated from the other product containing similar material]

Carcinogenicity

: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human

 

carcinogen). This classification is given to chemicals for which there is inadequate human

 

evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The

classification is based upon the development of lung tumors in rats receiving chronic inhalation exposures to free carbon black at levels that induce particle overload of the lung. Studies performed in animal models other than rats did not show any association between carbon black and lung tumors. Moreover, a two-year cancer bioassay using a typical toner preparation containing carbon black demonstrated no association between toner exposure and tumor development in rats.