TROUBLESHOOTING

Notice page printed

If you find that a notice page has been printed at the end of a print job, the print data received from the computer has not been printed as specified. Fix the problem as explained below and then try printing again.

What to do when a notice page is printed, 1

****************************************************

Notice Page

****************************************************

The incorrect driver is chosen, a normal output was not able to be excuted.

Please install the appropriate driver.

Please refer to the operation manual for the solution method.

What to do when a notice page is printed, 2

****************************************************

Notice Page

****************************************************

The IMC memory full error had occurred, a normal output was not able to be executed.

Please refer to the operation manual for the solution method.

The above notice page is printed if you attempt to print using the print driver for the dual function board when the dual function board is not installed. Change to the standard print driver and print again. If the standard print driver is not installed, install as explained in the Software Setup Guide.

Removing the software

If you need to remove the software, follow these steps.

1 Click the "start" button, and then click "Control Panel".

On Windows 95/98/Me/NT 4.0/2000, click the "Start" button, select "Settings", and then click "Control Panel".

2 Click "Add or Remove Programs".

On Windows 95/98/Me/NT 4.0/2000, double-click the "Add/Remove Programs" icon.

3 Select the printer/scanner driver for the machine and Button Manager from the list, and remove the software.

For more information, refer to your operating manual or to the help files for your operating system.

The above notice page is printed when a print job containing more data than can be held in the memory of the dual function board is sent to the machine. To fix the problem, disable the ROPM function. If you need to use the ROPM function, set the print quality in the printer driver to "Draft", or increase the amount of memory on the dual function board.

The IMC memory is used to temporarily hold Note print data when the ROPM function is used.

This memory is also used to temporarily hold the original image during copying. The proportion of IMC memory allocated to the printer function can be changed in the user programs of copy mode. See the user program "Memory allocated to printer mode". (p.46) It is also possible to expand memory by adding on a commercially available memory module. For more information on expansion memory, contact a SHARP service center.