Sharp AE-X9FR, AY-XP7FR AY-XP12FR- AE-X12FR, AYXP7FR, Model, Indoor Unit, Outdoor Unit, Items

Models: AE-X12FR AE-X9FR AE-X7FR AY-XP9FR AY-XP7FR AY-XP12FR

1 14
Download 14 pages 63.97 Kb
Page 4
Image 4

AYXP7FR

3. AY-XP12FRAE-X12FR

 

 

 

MODEL

INDOOR UNIT

OUTDOOR UNIT

ITEMS

 

 

 

AY-XP12FR

AE-X12FR

Cooling capacity(Min. > Max.)

 

kW

3.5 (0.9 - 3.8)

 

Heating capacity(Min. > Max.)

 

kW

4.0 (0.9 - 6.0)

 

Moisture removal(at cooling)

 

Liters/h

 

 

Electrical data

 

 

 

 

 

Phase

 

 

 

Single

 

Rated frequency

 

 

Hz

50

 

Rated voltage

 

 

V

230

 

Rated current

Cool

 

A

5.0 (1.1 - 8.2)

 

(Min - Max.)

Heat

 

A

4.8 (1.0 - 8.0)

 

Rated input

Cool

 

W

1090 (210 - 1300)

 

(Min - Max.)

Heat

 

W

1030 (180 - 1900)

 

Power factor

Cool

 

%

95

 

 

Heat

 

%

93

 

Compressor

Type

 

Hermetically sealed rotary type

 

Model

 

5RS102XBE01

 

 

Oil charge

 

320cc (RB68A or Freol Alpha 68M)

Refrigerant system

Evaporator

 

Louver Fin and Grooved tube type

 

Condenser

 

Corrugate Fin and Grooved tube type

 

Control

 

Expansion valve

 

 

Refrigerant (R410A)

1030g

 

 

De-lce system

Micro computer controled reversed systems

Noise level

High

 

dB(A)

40

48

(at cooling)

Low

 

dB(A)

 

Soft

 

dB(A)

28

Fan system

 

 

 

 

 

Drive

 

 

 

Direct drive

 

Air flow quantity

High

 

m3/min.

9.8

26.7

(at cooling)

Low

 

m3/min.

8.5

 

Soft

 

m3/min.

6.9

Fan

 

 

 

Cross flow fan

Propeller fan

Connections

 

 

 

 

 

Refrigerant coupling

 

 

 

Flare type

 

Refrigerant tube size Gas, Liquid

3/8", 1/4"

 

Drain piping mm

 

 

 

O.D φ18

 

Others

 

 

 

 

 

Safety device

 

 

 

Compressor: Thermal protector

 

 

 

 

Fan motors: Thermal fuse

 

 

 

 

Fuse, Micro computer control

Air filters

 

 

 

Polypropylene net (Washable)

Net dimensions

Width

 

mm

790

730

 

Height

 

mm

278

540

 

Depth

 

mm

198

250

Net weight

 

 

kg

10

37

NOTE: The condition of star”” marked item are ‘ISO5151’ : 1994(E), contition T1.