[4] PERFORMANCE CURVES
NOTE
1)Indoor fan speed: Hi
2)Vertical adjustment louver "45°”, Horizontal adjustment louver "front"
3)Indoor air temp. : Cooling 27°C, Heating 20°C
4)Power source : 230V, 50Hz
1. AY-XP7FR
1.1. At Cooling
Input(W) | 600 | |
400 | ||
| 500 | |
| 300 | |
capacity(kW) | 2.6 | |
| ||
| 2.4 | |
Cooling | 2.2 | |
2.0 | ||
|
25 | 30 | 35 | 40 |
Outside air temp.(ºC)
2. AY-XP9FR
2.1. At Cooling
Input(W) | 900 | |
700 | ||
| 800 | |
| 600 | |
capacity(kW) | 3.2 | |
| ||
| 3.0 | |
Cooling | 2.8 | |
2.6 | ||
| ||
| 2.4 |
25 | 30 | 35 | 40 |
Outside air temp.(ºC)
AYXP7FR
1.2. At Heating
Input(W) | 600 |
400 | |
| 500 |
capacity(kW) | 3.0 |
| |
| 2.5 |
| 2.0 |
Heating | 1.5 |
|
0 | 5 | 7 | 10 |
Outside air temp.(ºC)
2.2. At Heating
Input(W) | 800 |
600 | |
| 700 |
capacity(kW) | 3.5 | |
| ||
Heating | 3.0 | |
2.5 | ||
| ||
| 2.0 |
0 | 5 | 7 | 10 |
Outside air temp.(ºC)
4 – 2