| AYXP7FR |
|
|
|
|
|
|
|
|
| |
Status of | Indication | Malfunction | Content of diagnosis | Inspection location/method |
| Remedy | |||
indoor/ | by LED1 | No. dis- |
|
|
|
|
|
| |
outdoor | on out- | played on |
|
|
|
|
|
| |
units | door unit | main unit |
|
|
|
|
|
| |
| *2 | display sec- |
|
|
|
|
|
| |
|
| tion *1 |
|
|
|
|
|
| |
|
| Main | Sub- | Main category |
|
|
|
| |
|
| cate- | cate- |
|
|
|
|
|
|
|
| gory | gory |
|
|
|
|
|
|
Indoor/ | 11 | 11 | Outdoor unit DC | Outdoor unit DC fan | (1) | Check connector CN3 of | (1) | Correct the installa- | |
outdoor | times |
|
| fan | rotation error |
| the outdoor unit DC fan |
| tion. |
units in |
|
|
|
|
|
| motor for secure installa- |
|
|
complete |
|
|
|
|
|
| tion. |
|
|
shutdown |
|
|
|
|
| (2) | Check the outdoor unit fan | (2) | Replace the outdoor |
|
|
|
|
|
|
| motor for proper rotation. |
| unit fan motor. |
|
|
|
|
|
| (3) | Check fuse FU3. | (3) | Replace the outdoor |
|
|
|
|
|
|
|
|
| unit control PWB |
|
|
|
|
|
|
|
|
| assembly. |
|
|
|
|
|
| (4) | Outdoor unit control PWB | (4) | Replace the outdoor |
|
|
|
|
|
|
|
|
| unit control PWB |
|
|
|
|
|
|
|
|
| assembly. |
Indoor/ | 13 | 13 | DC compressor | Compressor startup | (1) | Check the colors (red, | (1) | Correct the installa- | |
outdoor | times |
|
|
| error |
| white, orange) of the com- |
| tion. |
units in |
|
|
|
|
|
| pressor cords for proper |
| (U: Red, V: White, W: |
complete |
|
|
|
|
|
| connection. (PWB side, |
| Orange) |
shutdown |
|
|
|
|
|
| compressor side) |
|
|
|
|
|
| Compressor rota- | (2) | Check if the IPM terminal | (2) | Replace the outdoor | |
|
|
|
|
| tion error |
| resistance values are uni- |
| unit control PWB |
|
|
|
|
| (120° energizing |
| form. |
| assembly. |
|
|
|
|
| error) | (3) | No abnormality found in | (3) | Replace the outdoor |
|
|
|
|
|
|
| above inspections (1) and |
| unit control PWB |
|
|
|
|
|
|
| (2). |
| assembly. |
|
|
|
|
|
| (4) | No abnormality found in | (4) | Replace the compres- |
|
|
|
|
|
|
| above inspections (1) |
| sor. |
|
|
|
|
|
|
| through (3). |
|
|
Indoor/ | 14 | 14 | Outdoor unit | PAM over voltage | (1) | Check the AC power sup- | (1) | Connect stable power | |
outdoor | times |
|
| PAM | error |
| ply voltage for fluctuation. |
| supply. |
units in |
|
|
|
| Compressor rota- | (2) | No abnormality found in | (2) | Replace the outdoor |
complete |
|
|
|
| tion error |
| above inspection (1). |
| unit control PWB |
shutdown |
|
|
|
|
|
|
|
| assembly. |
Indoor/ |
|
|
| PAM clock error | (1) | Check the PAM clock for | (1) | Replace the outdoor | |
outdoor |
|
|
|
|
|
| proper input. |
| unit control PWB |
units in |
|
|
|
|
|
|
|
| assembly. |
operation |
|
|
|
|
|
|
|
|
|
Indoor |
| 17 | Wires between | Serial | (1) | Check the wires between | (1) | Connect stable power | |
unit in |
|
|
| units |
|
| units. |
| supply. |
operation |
|
|
|
|
| (2) | Check voltage between | (2) | Replace the outdoor |
Outdoor |
|
|
|
|
|
| Nos. 1 and 2 on the |
| unit control PCB |
unit in |
|
|
|
|
|
| indoor/outdoor unit termi- |
| assembly. |
complete |
|
|
|
|
|
| nal boards. |
|
|
shutdown |
|
|
|
| Outdoor unit does | (1) | Check the wires between | (1) | Correct the wiring. |
|
|
|
|
| not turn on due to |
| units. |
|
|
|
|
|
|
| erroneous wiring | (2) | Check the outdoor unit | (2) | Replace the fuse/out- |
|
|
|
|
|
|
| fuse. |
| door unit control PCB |
|
|
|
|
|
|
|
|
| assembly. |
|
|
|
|
|
| (3) | Check | (3) | Replace the outdoor |
|
|
|
|
|
|
| voltages on the PWB. |
| unit control PCB |
|
|
|
|
|
|
| Check resistance between |
| assembly. |
|
|
|
|
|
|
| IPM terminals. |
|
|
|
|
|
|
|
| (4) | Check pins No. 5 and 7 of | (4) | Replace the outdoor |
|
|
|
|
|
|
| connector CN3 of the out- |
| unit fan motor. |
|
|
|
|
|
|
| door unit fan motor for |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| (5) | Outdoor unit control PCB | (5) | Replace the outdoor |
|
|
|
|
|
|
|
|
| unit control PCB |
|
|
|
|
|
|
|
|
| board. |
|
| 18 |
| Serial | (1) | Check the wires between | (1) | Correct the wiring. | |
|
|
|
|
|
|
| units. |
|
|
|
|
|
| Serial erroneous wir- | (1) | Check the wires between | (1) | Correct the wiring. | |
|
|
|
|
| ing |
| units. |
|
|
3 – 16