Sharp CV-P09FR operation manual Dehumidification Mode, E-10, To Turn Off, “OPEN position”

Models: CV-P09FR

1 22
Download 22 pages 20.53 Kb
Page 12
Image 12
DEHUMIDIFICATION MODE

DEHUMIDIFICATION MODE

In this mode, the air conditioner dehumidifies the room.

Drainage nozzle

Stopcock

“OPEN position”

1 Remove the exhaust hose (See Page 8)

2 Turn the drainage nozzle to the OPEN position.

3 Pull the stopcock out from the drainage nozzle.

When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.

Always perform this procedure with the unit turned off. Drain water will spout out if attempted during operation.

Hose clamp

Hose

7

6

4 Insert the hose clamp into a standard commercially-available hose (12.7 mm in- ner diameter, 16.7 mm outer diameter)

5 Attach the hose to the drainage nozzle, and secure it with the hose clamp.

Depending on room condition, approximately 28 liters of water per day (24 hours) will be dehumidified.

Prepare some kind of bucket of appropriate size to collect drain water, or take some appro- priate measure to drain the water outside of the room, so that drain water will not overflow or soak your room.

Set the hose sloping downwards for easier drainage. Moreover, do not bend the hose at any point, nor allow the end to be submerged in water.

6 Press the MODE button to select DEHU- MIDIFICATION mode.

COOL DEHUM FAN VENT

7 Presstion. the ON/OFF button to start opera-

The red OPERATION lamp ( “OPEN position”E-10Manual background )on the unit will light.

The temperature cannot be set.

The fan speed is preset to AUTO and cannot be changed.

TO TURN OFF

Press the ON/OFF button again.

The red OPERATION lamp ( Manual background )on the unit will turn off.

CAUTION

The unit generates heat during dehumidification mode and the room temperature will rise. Install the exhaust hose if you do not want the room temperature to rise. This will help to slightly drop the room temperature, but dehumidification performance will become less effective than when operating without the exhaust hose.

E-10