DRAINAGE

DRAINAGE

Prepare for drainage and drain out water within the unit in the following cases.

If the unit stops operating and the TIMER ( E-17 ), OPERATION ( Manual backgroundManual backgroundManual background ) and TURBO COOL ( Manual background ) lamps are blinking. (This indicates that the water tank inside the unit is full.)

1 Make sure to turn the unit off.

2 Turn the drainage nozzle to the OPEN position.

3 Pull the stopcock out from the drainage nozzle.

When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.

4 Insert the hose clamp into a standard com- mercially available hose (12.7 mm inner di- ameter, 16.7 mm outer diameter).

5 Attach the hose to the drainage nozzle, and secure it with the hose clamp.

Prepare for draining, as drain water will come out through the hose during operation.

6 Press the AUX. button on the unit twice.

• The water will drain out through the drainage hose. Mximum amount of water that may be drained out is approximately 2 liters.

• The OPERATION, TIMER and TURBO COOL lamps will be blinking.

Drainage nozzle

Stopcock

“OPEN position”

Hose clamp

Hose

ENGLISH

7 When drainage water stops running out from the hose, turn the unit off by pressing AUX. button.

• This would take about one minute.

8 Remove the hose from the drainage nozzle, and replace the stopcock.

• Keep the hose clamp in case of re-used.

9 Turn the drainage nozzle to the CLOSE position.

Whenever the unit is moved (to provent water within the unit from spilling). When the unit is not used for a long time.

1 Carry out the above procedures from 1 to 5. 2 Press the AUX. button on the unit.

The water will drain out through the drainage hose.

Mximum amount of water that may be drained out is approximately 2 liters.

The OPERATION lamps will light.

3 When drainage water stops running out from the hose, turn the unit off by pressing AUX. button.

• This would take about one minute.

4 Remove the hose from the drainage nozzle, and replace the stopcock.

• Keep the hose clamp in case of re-used.

5

Turn the drainage nozzle to the CLOSE position.

 

6

Remove the stopcock from the drainpipe nozzle, and completely drain any

water within the unit.

 

 

• Always prepare a receptacle to collect the water

Stopcock

 

before draining. Mximum amount of water that may

 

 

be drained out is approximately 0.2 liters.

 

7

Replace the stopcock to the drainpipe nozzle.

Drainpipe nozzle

E-17