Installation Manual
Electrical Connections
The installer or consumer is responsible for connecting the power supply cord to the connection block located behind the back panel access cover.
This range may be connected by means of permanent “hard wiring” (flexible armored or nonmetallic shielded copper or aluminum cable), or by means of a power supply cord kit. Only a power supply cord kit rated at 240 volts or 208 volts and 50 amperes and marked for use with ranges shall be used. Cord must have either 3 or 4 conductors to match electric receptacle. The power cord kit is not included so must be purchased at an appliance store.
For mobile homes, new installations, recreational vehicles or areas where local codes do not permit grounding through neutral, a 4 conductor power supply cord kit rated at 240 volts or 208 volts minimum, 50 amperes and marked for use with ranges should be used.
Terminals on end of wires must be either closed loop or
Risk of fire or electrical shock exists if an incorrect size range cord kit is used, the installation instructions are not followed precisely or a strain relief clamp is not used.
Do not loosen the nuts which secure the factory- installed range wiring to the terminal block while connecting range. Electrical failure or loss of electrical connection may occur.
Electrical Shock Hazard
•DISCONNECT POWER TO THE CIRCUIT BREAKER OR FUSE BOX BEFORE MAKING THE ELECTRICAL CONNECTION.
•Electrical ground is required on this range.•Do not connect to the electrical supply until range is permanently grounded.
•This range must be connected to a grounded, metallic, permanent electrical system or the grounding connector of the power cord should be connected to the grounding terminal or wire lead on the range.
•Failure to heed these warnings could result in a fire, personal injury or electrical shock.
Rating plate
208/240 Volt Connection Instructions
The range can be set for 208V or 240V. The voltage setting for your range is
1Locate the voltage switch on the lower back side of the range.
2Remove the screw and rotate the switch plate 180˚ as indicated in the Figure 4.
3Reinsert the switch plate and replace screw as indicated in Figure 5. The voltage setting is indicated by the visible marking.
|
| screw |
| 240V | 208V |
180˚ | screw |
|
|
|
Figure 4 | Figure 5 |
3&
Figure 6A illustrates
Figure 6B illustrates
Figure 6A | Figure 6B |
Access to Terminal Block
Loosen screw on rear access cover and pull down as illustrated in Figure 7 to access terminal block wiring connection.
strain relief clamp
screw
model and serial number location |
|
|
The rating plate, including model and serial number, is located on |
|
|
the faceplate behind the Microwave Drawer front. | Figure 7 | Figure 8 |
| ||
|
|