TROUBLESHOOTING

Before calling for repair, please review the list below, since the problem may not be a unit malfunction.

SYMPTOM

REMEDY (not a malfunction)

 

 

The Remote Control does not

• Have the batteries been depleted?

work

• Are the batteries inserted correctly?

 

• Is a fluorescent lighting in the room flickering due to service

 

life? (Refer to E-7,E-11)

 

 

Odors and smoke are not re-

• Clean the filters if they appear to be heavily soiled.

moved

(Refer to E-16,E-17)

 

 

The CLEAN-SIGN Light lights

• Is the opening of the odor sensor blocked or the sensor filter

green even when the air is im-

clogged? (Refer to E-18)

pure

• The air could be impure at the time the unit was plugged in.

 

(Refer to E-9)

 

 

The CLEAN-SIGN Light lights

• Is the sensor filter dirty or clogged?

orange or red even when the air

The sensitivity of the sensor becomes unstable when the open-

is clean

ing of the dust sensor is dirty or is clogged.

 

Remove dust from the sensor filter. (Refer to E-18)

 

 

The Plasmacluster Indicator

• When in Clean Mode ( or Ion Control Mode), the Plasmaclus-

Light remains green (blue) and

ter Indicator Light color will not change.

does not change

 

 

 

A clicking or ticking sound is

• Clicking sound is emitted when the unit is in the Ion Control

heard from the unit

Mode.

 

If the sound is irritating, set the unit away from you.

 

• Ticking sound is emitted when the unit is generating ions.

 

If the sound is irritating, such as when sleeping, set the unit

 

away from you.

 

 

A ticking sound is sometimes

• A sound is sometime low, loud or not at all, but the effect of the

heard from the unit and is not

Plasmacluster ion is the same.

sometimes heard.

 

 

 

The discharged air has an

• Check to see if the filters are heavily soiled.

aroma or odor.

Care the Washable Active Carbon Filter or replace filters.

 

(Refer to E-16,E-19)

 

• Check to see if the Washable Active Carbon Filter is dried thor-

 

oughly after cleaning it.

 

• Very low concentration of ozone generated by the

 

Plasmacluster ion generator may have a odor.

 

This is harmless and will not affect the human body. Also, the

 

ozone will break down quickly and will not accumulate in the

 

room environment.

 

 

The unit does not operate when

• Is the unit installed in a location that is difficult for the sensors

cigarette smoke is in the air.

to detect cigarette smoke?

 

• Are the odor or dust sensor openings blocked or clogged?

 

(In this case, clean the openings.) (Refer to E-18)

 

 

The Filter Indicator Light re-

• After cleaning or replacing filters, connect the power cord to

mains activated even after

an outlet and press the Filter Reset Button on the main unit or

washing or replacing filter.

on the remote control. (Refer to E-17)

 

 

The Plasmacluster Indicator

• Check to see if the Display OFF Mode on the Remote Control

Light or the CLEAN-SIGN Light

is selected. If so, then press the Display ON/OFF Button on

will not activate.

the Remote Control to activate the indicator light.

 

(Refer to E-15)

 

 

ENGLISH

E-21

Page 23
Image 23
Sharp FP-N60CX operation manual Troubleshooting, Remedy not a malfunction

FP-N60CX specifications

The Sharp FP-N60CX is a cutting-edge air purifier designed to enhance indoor air quality for homes and offices. Equipped with advanced technologies, this device effectively filters and cleans the air, making it an excellent choice for individuals who prioritize health and wellness.

One of the standout features of the FP-N60CX is its Plasmacluster technology. This innovative system releases positive and negative ions into the air, which work to neutralize harmful microorganisms, including viruses and bacteria. This helps create a healthier environment by minimizing airborne pollutants, making it particularly beneficial for allergy sufferers and those with respiratory conditions.

The FP-N60CX boasts a high-performance HEPA filter that captures 99.97% of particles as small as 0.3 microns. This includes dust, pollen, pet dander, and other allergens, ensuring that the air breathed indoors is clean and safe. The HEPA filter is complemented by an activated charcoal filter that effectively absorbs odors from cooking, pets, and smoke, further improving air quality.

In terms of usability, the Sharp FP-N60CX features a user-friendly interface with an intuitive control panel. It includes multiple fan speeds, allowing users to customize the air purification intensity based on their needs. The device also operates quietly, making it ideal for bedrooms and quiet spaces.

Another key characteristic of the FP-N60CX is its coverage area. It is designed to purify the air in medium to large rooms, making it versatile for various applications from living rooms to offices. The 360-degree air intake system ensures that air is drawn in from all directions, maximizing its efficiency in purifying the air.

Additionally, the Sharp FP-N60CX is equipped with a filter replacement indicator that alerts users when it’s time to replace the filters. This feature helps maintain optimal performance and assures users that they are consistently breathing clean air.

In conclusion, the Sharp FP-N60CX combines advanced air purification technologies, such as Plasmacluster and HEPA filtration, with user-friendly features to create a reliable and efficient air purifier. Its ability to enhance indoor air quality makes it an essential addition to any home or workspace focused on creating a healthy living environment. Investing in the Sharp FP-N60CX is a step towards improving overall well-being and ensuring cleaner air for you and your loved ones.