Sharp KC-860EK, KC-850EK Humidifying Filter, Remove the Water Tank and Humidifying Tray

Models: KC-850EK KC-860EK

1 44
Download 44 pages 34 Kb
Page 16
Image 16
HUMIDIFYING FILTER

CARE AND MAINTENANCE

HUMIDIFYING FILTER

Care Cycle

Once a month or when the Filter Indicator Light is on.

Frequency of maintenance cycle will depend on the hardness or the impurities of the water that you use; the harder the water the more often descaling will be necessary.

Pay attention not to spill water when cleaning the filter.

1 Remove the Water Tank and

Humidifying Tray.

Humidifying filter

Humidifying

Tray

Water Tank

1 Remove the Water Tank and Humidifying

Tray

2 Remove the Humidifying Filter from the Humidifying Tray.

Avoid spilling water from the Humidifying Tray.

3 Preparing the descaling solu- tion.

Citric acid, available at some drugstores, or 100 % bottled lemon juice are used for descaling. Choose either one to use, and prepare the descaling solution.

<For using citric acid>

Dissolve 3 teaspoons of citric acid and 2 1/2 cups of lukewarm water in a suitable container, and stir well.

<For using lemon juice>

100 % bottled lemon juice can be used for descaling. Use only 100 % bottled lemon juice with no pulp (strain juice if necessary). Combine 1/4 cup lemon juice and 3 cups of lukewarm water in a con- tainer large enough to hold the Humidify- ing Filter and stir well.

4 Pre-soak the Humidifying Filter in the solution for 30 minutes before cleaning.

When using lemon juice, it is recommended to pre- soak longer than citric acid.

5 Rinse the Humidifying Filter re- peatedly with lukewarm water to remove all the solution resi- due.

Inadequate rinsing may cause odour and affect the performance and/or appear- ance of the unit.

* Do not scrub the Humidi- fying Filter, rinse gently under lukewarm water only.

6 Attach the Humidifying Filter to the Humidifying Tray, and replace the Humidifying Tray in the unit.

•The Humidifying Filter will not fit if placed in backwards. Be sure there is no gap between the Humidifying Tray and the unit when the Humidifying Tray is replaced in the unit. The unit may not operate properly if the Humidifying Tray is not properly replaced in the unit.

•When not using the unit for a long peri- ods of time, dry the Humidifying Filter completely before replacing.

7Plug in the unit, turn power ON, and press the Filter Reset Button on the display for more than 3 seconds to reset.

You may notice reddish-brown or white deposits forming on the surface of the Humidifying Filter. These impurities (cal- cium, etc.) are due to the impurities con- tained in tap water; this is not a defect. Replace the Humidifying Filter when it is covered completely in white deposits.