Sharp MD-SR50H operation manual MiniDisc System Limitations, 4140, References, Symptom

Models: MD-SR50H

1 48
Download 48 pages 46.95 Kb
Page 41
Image 41
MiniDisc System Limitations

MiniDisc System Limitations

The unit may have the following symptoms whilst recording or editing. The unit is not out of order.

SYMPTOM

 

LIMITATIONS

 

 

 

“DISC FULL” or “TOC FULL” appears even though the MiniDisc still has re- cording time left.

More than 255 tracks (maximum) cannot be recorded regardless of the re- cording time.

If the MiniDisc is recorded or edited repeatedly or if it has scratches (record- ing skips scratched parts), you may not be able to record the maximum tracks above.

References

The remaining recording time does not The unit does not count non-recorded portions that last 12 or fewer seconds increase even though you erased tracks. to display the remaining recording time. The time may not increase even if

you erase short tracks.

The total of the recorded time and the One cluster (approximately 2 seconds) is the minimum unit for recording. remaining time does not match the maxi- For example, a 3-second track uses 2 clusters (approximately 4 seconds).

mum recordable time.Therefore, the actual recordable time may be shorter than the displayed time.

Combine function does not work. A MiniDisc on which recording and editing are repeated may not allow the combine function.

Sound skips in fast reverse/forward. One track is divided and recorded in separate places on a repeatedly re- corded or edited MiniDisc.

Sound may skip.

A track number is created in the middle A track number may be created if there are scratches or dust on the MiniDisc. of a track.

4140

Page 41
Image 41
Sharp MD-SR50H operation manual MiniDisc System Limitations, 4140, References, Symptom