Sharp MMD24B Refer to the disassembly instructions found on Page, Test Procedures, Component Test

Models: MMD24S MMD24B

1 38
Download 38 pages 30.87 Kb
Page 16
Image 16
Refer to the disassembly instructions found on Page 27.

MMD24S

MMD24B

TEST PROCEDURES

PROCEDURE

COMPONENT TEST

LETTER

 

Refer to the disassembly instructions found on Page 27.

GMAGNETRON ASSEMBLY TEST

1.Disconnect the power supply cord.

2.Open the drawer and keep it open.

3.To discharge high voltage capacitor, wait for 60 seconds.

4.To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm.

5.To test for a shorted magnetron, connect the ohmmeter leads between the magnetron filament leads and chassis ground. This test should indicate an infinite resistance. If there is little or no resistance the magnetron is grounded and must be replaced.

6.Reconnect all leads removed from components during testing.

7.Reassemble the unit.

8.Reconnect the power supply cord.

9.Run the oven and check all functions.

MICROWAVE OUTPUT POWER

The following test procedure should be carried out with the microwave oven in a fully assembled condition.

HIGH VOLTAGES ARE PRESENT DURING THE COOK CYCLE, SO EXTREME CAUTION SHOULD BE OBSERVED.

Power output of the magnetron can be measured by performing a water temperature rise test. This test should only be used if above tests do not indicate a faulty magnetron and there is no defect in the following components or wiring: This test will require a 16 ounce (453cc) measuring cup and an accurate mercury thermometer or thermocouple type temperature tester. For accurate results, the following procedure must be followed carefully:

1.Fill the measuring cup with 16 oz. (453cc) of tap water and measure the temperature of the water with a thermometer or thermocouple temperature tester. Stir the thermometer or thermocouple through the water until the temperature stabilizes. Record the temperature of the water.

2.Place the cup of water in the oven. Operate oven at POWER 10(HIGH) selecting more than 60 seconds cook time. Allow the water to heat for 60 seconds, measuring with a stop watch, second hand of a watch or the digital read-out countdown.

3.Remove the cup from the oven and again measure the temperature, making sure to stir the thermometer or thermocouple through the water until the maximum temperature is recorded.

4.Subtract the cold water temperature from the hot water temperature. The normal result should be 28ο to 54οF (16ο to 30οC) rise in temperature. If the water temperatures are accurately measured and tested for the required time period the test results will indicate if the magnetron tube has low power output (low rise in water temperature) which would extend cooking time or high power output (high rise in water temperature) which would reduce cooking time. Because cooking time can be adjusted to compensate for power output, the magnetron tube assembly should be replaced only if the water temperature rise test indicates a power output well beyond the normal limits. The test is only accurate if the power supply line voltage is 120 volts and the oven cavity is clean.

HTHERMAL CUT-OUT TEST

1.Disconnect the power supply cord.

2.Open the drawer and keep it open.

3.To discharge high voltage capacitor, wait for 60 seconds.

4.A continuity check across the thermal cut-out terminals should indicate a closed circuit unless the temperature of the thermal cut-out reaches approximately 293οF(145οC).

An open thermal cut-out indicates overheating of the oven, exchange the oven thermal cut-out and check inside of oven cavity and for improper setting of cooking time or operation of control unit. Check for restricted air flow through the vent holes of the oven cavity, especially the cooling fan and air guide.

5.Reconnect all leads removed from components during testing.

6.Reassemble the unit.

7.Reconnect the power supply cord.

8.Run the unit and check all functions.

CAUTION: IF THE THERMAL CUT-OUT INDICATES AN OPEN CIRCUIT AT ROOM TEMPERATURE, REPLACE THERMAL CUT-OUT.

16

Page 16
Image 16
Sharp MMD24B, MMD24S manual Refer to the disassembly instructions found on Page, Test Procedures, Component Test, Letter