SWITCH ANGLE REMOVAL/ADJUSTMENT

 

SWITCH ANGLE REMOVAL/ADJUSTMENT

 

SWITCH ANGLE REMOVAL

Fig. S-1

(Locate either the right or left switch angle)

 

1.

Follow the Microwave Drawer disassembly as previously stated

 

2.

Open the drawer and keep it open.

 

3.

To discharge the high voltage capacitor, wait for 60 seconds.

 

4.

To remove switch, remove screw (1) holding switch to switch angle

 

 

(Fig. S-1).

 

5.

To replace switch angle, remove bottom cover and remove the 2 screws

 

 

holding the switch lever (Fig. S-2).

 

6.

Proceed in reverse to reinstall.

 

7.

Adjust switch.

 

Fig. S-2

ACTUATOR REMOVAL/ADJUSTMENT

1.Follow the Microwave Drawer disassembly as previously stated

2.Open the drawer and keep it open.

3.To discharge the high voltage capacitor, wait for 60 seconds.

4.Locate either the right or left actuator and remove the 2 screws holding the actuator to the door support angles.

5.Relpace with the new actuator (Fig. A-3).

Actuator adjustment

6.It is very critical that proper adjustment is made to actuator.

7.Adjust each actuator to fully depress ("0" gap) switch lever switches on left and right side (Fig. A-4).

NOTE: If this adjustment is not adjusted correctly, it will effect the performance of the Auto Drawer.