Setting up the Projector Using
Disconnecting All Connec-
tions ([D]Disconnect All)
Setting Auto Logout Time
(ADVANCED[1]Auto Logout Time)
It is possible to disconnect all the TCP/IP connections currently recognized by the projector. Even if the COM Redirect port is fixed in the Busy status due to a problem, it is possible to force the Ready status back by carrying out this disconnection.
setup>d | 1 |
Disconnect All Connections(y/n)?y | 2 |
Now Disconnecting... |
|
|
|
1 Enter “d” and press the “Enter” key.
2 Enter “y” and press the “Enter” key.
Note
•If Disconnect All is performed, the connection to the projector via network will be forcibly disconnected.
Entering ADVANCED
SETUP MENU
([A]Advanced Setup)
Enters ADVANCED SETUP MENU.
setup>a | 1 |
********************** ADVANCED SETUP MENU ************************* | |
[1]Auto Logout Time | [2]Data Port |
[5]Network Ping Test |
|
[6]Accept IP Addr(1) | [7]Accept IP Addr(2) [8]Accept IP Addr(3) |
[9]Accept All IP Addr | [0]Search Port |
[!]Restore Default Setting [Q]Return to Main Menu
advanced>
1 Enter “a” and press the “Enter” key.
If there is no input after a fixed time, the projector automatically disconnects network connection using the Auto Logout function. It is possible to set the time until the projector is automatically disconnected in units of a minute (from 1 to 65535 minutes).
advanced>1 |
|
| 1 | |
Valid range | : 0 to 65535 (minute) |
|
| |
note: if you enter “0”, auto logout function will be disable. |
|
| ||
Auto Logout Time: 5 | 2 | |||
Please Enter | :15 |
| ||
(change) |
|
|
| |
| * | |||
|
|
|
1 Enter “1” and press the “Enter” key.
2 Enter numerical value and press the “Enter” key.
Display set numerical value (*).
Note
•If the set value is made 0, the Auto Logout function is disabled.
•If an invalid number is entered, an error message (“Parameter Error!”) will be displayed and the screen returns to the ADVANCED SETUP MENU.
Data Port Setting
(ADVANCED[2]Data Port)
Setting of TCP port number. It is possible to set in the range of 1025 to 65535.
advanced>2 |
|
| 1 | |
Valid range | :1025 to 65535 |
|
| |
Data Port | :10002 |
| 2 | |
Please Enter | :10005 |
| ||
(change) |
|
| * | |
|
|
1 Enter “2” and press the “Enter” key.
2 Enter numerical value and press the “Enter” key.
Display set numerical value (*).
Note
•Set according to need. Normally, use with the factory default setting.