Setting up the Projector Using RS-232C or Telnet

Disconnecting All Connec-

tions ([D]Disconnect All)

Setting Auto Logout Time

(ADVANCED[1]Auto Logout Time)

It is possible to disconnect all the TCP/IP connec- tions currently recognized by the projector. Even if the COM Redirect port is fixed in the Busy status due to a problem, it is possible to force the Ready status back by carrying out this disconnection.

setup>d

1

Disconnect All Connections(y/n)?y

2

Now Disconnecting...

 

 

 

1Enter “d” and press the “Enter” key.

2 Enter “y” and press the “Enter” key.

Note

If Disconnect All is performed, the connection to the projector via network will be forcibly discon- nected.

Entering ADVANCED SETUP MENU

([A]Advanced Setup)

Enters ADVANCED SETUP MENU.

setup>a

1

******************** ADVANCED SETUP MENU ***********************

[1]Auto Logout Time

[2]Data Port

[5]Network Ping Test

 

[6]Accept IP Addr(1)

[7]Accept IP Addr(2) [8]Accept IP Addr(3)

[9]Accept All IP Addr

[0]Search Port

[!]Restore Default Setting [Q]Return to Main Menu

advanced>

1 Enter “a” and press the “Enter” key.

If there is no input after a fixed time, the projector automatically disconnects network connection using the Auto Logout function. It is possible to set the time until the projector is automatically disconnected in units of a minute (from 1 to 65535 minutes).

advanced>1

 

 

1

Valid range

: 0 to 65535 (minute)

 

 

note: if you enter “0”, auto logout function will be disable.

 

 

Auto Logout Time : 5

 

 

Please Enter

:15

 

 

2

 

 

(change)

—> 15

*

1Enter “1” and press the “Enter” key.

2Enter numerical value and press the“Enter”key. Display set numerical value (*).

Note

If the set value is made 0, the Auto Logout func- tion is disabled.

If an invalid number is entered, an error message (“Parameter Error!”) will be displayed and the screen returns to the ADVANCED SETUP MENU.

Data Port Setting

(ADVANCED[2]Data Port)

Setting of TCP port number. It is possible to set in the range of 1025 to 65535.

advanced>2

 

 

1

Valid range

:1025 to 65535

 

 

Data Port

:10002

 

 

 

Please Enter

:10005

 

 

2

 

 

(change)

—> 10005

*

1Enter “2” and press the “Enter” key.

2Enter numerical value and press the“Enter”key. Display set numerical value (*).

Note

Set according to need. Normally, use with the fac- tory default setting.

-27

Page 27
Image 27
Sharp PG-F320W Disconnecting All Connec, Setting Auto Logout Time, Entering Advanced Setup Menu, Data Port Setting