Maintenance Indicators
■The warning lights (power indicator, lamp indicator and temperature warning indicator) on the projector indicate problems inside the projector.
■If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate red, and the projector will enter Standby mode. After the projector has entered Standby mode, follow the procedures given below.
Top View Temperature warning indicator
Lamp indicator
Power indicator
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location, the temperature warning indicator will blink. And if the temperature keeps on rising,
“” will illuminate in the lower left corner of the picture with the temperature warning indicator blinking. If this state continues, the lamp will turn off, the cooling fan will run and then the projector will enter Standby mode. When you fi nd the temperature warning indicator blinking, be sure to perform the measures described on page 55.
About the lamp indicator
■When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will be displayed on the screen. When the percentage becomes 0%, it will change to (red), the lamp will automatically turn off and then the projector will automatically enter Standby mode. At this time, the lamp indicator will illuminate in red.
■If you try to turn on the projector a fourth time without replacing the lamp, the projector will not turn on.
Indicators on the Projector
Power indicator | Red on | Normal (Standby) |
| Green on | Normal (Power on) |
| Red blinks | Abnormal (See page 55.) |
| Green blinks | Normal (Cooling) |
Lamp indicator | Green on | Normal |
| Green blinks | The lamp is warming up. |
| Red on | The lamp is shut down abnormally or requires to be |
|
| changed. (See page 55.) |
Temperature | Off | Normal |
warning indicator | Red on/Red blinks | The internal temperature is abnormally high. (See page 55.) |
54