Regarding the Lamp (Continued)

4 Remove the lamp unit.

Securing

• Loosen the securing screw from the lamp

screw

unit. Hold the lamp unit and pull it in the

 

direction of the arrow. At this time, keep

 

the lamp unit horizontal and do not tilt it.

 

5 Insert the new lamp unit.

• Press the lamp unit fi rmly into the lamp unit compartment to align the lamp connectors. Fasten the securing screw.

6 Replace the lamp unit cover.

• Slide the lamp unit cover horizontally back into place and align the tabs (1). Then tighten the user service screw (2) to secure the lamp unit cover.

Info

• If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.

Info

• Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode.

1 Connect the power cord.

AC socket

• Plug the power cord into the AC socket of

 

the projector.

 

2 Reset the lamp timer.

• While simultaneously holding down MENU, ENTER and R on the projector, press STANDBY/ON on the projector and keep all four buttons pressed down until the lamp indicator starts blinking green.

“LAMP 0000H” is displayed, indicating that the lamp timer is reset.

STANDBY/ON button

ENTER button

MENU button

Rbutton

58