Controlling the Monitor with a PC (RS-232C)

Initialization/Functional Restriction Setting (FUNCTION) menu

Function

Command

Direction

Parameter

Reply

 

Control/Response contents

ALL RESET

RSET

W

0

 

 

 

ADJUSTMENT LOCK

ALCK

WR

0-2

 

0-2

0: OFF, 1:ON 1, 2:ON 2

OSD DISPLAY

LOSD

WR

0-2

 

0-2

0: ON 1, 1: OFF, 2: ON 2

LED

OFLD

WR

0-1

 

0-1

0: ON, 1: OFF

TEMPERATURE ALERT

TALT

WR

0-2

 

0-2

0: OFF, 1: OSD & LED, 2: LED

STATUS ALERT

SALT

WR

0-2

 

0-2

0: OFF, 1: OSD & LED, 2: LED

 

 

 

 

 

 

 

*

-

-

-

-

-

-

Others

Function

Command

Direction

Parameter

Reply

Control/Response contents

*

VOLUME

VOLM

WR

0-31

0-31

 

-

BRIGHT

VLMP

WR

0-31

0-31

 

-

TEMPERATURE SENSOR

DSTA

R

 

0

Internal temperature normal

 

 

 

 

 

1

Internal temperature abnormal has occurred and the monitor is in

 

 

 

 

 

 

standby mode

 

 

 

 

 

2

Internal temperature abnormal occurred (To delete the information of

 

 

 

 

 

temperature abnormal, turn off the main power.)

 

 

 

 

 

 

 

 

 

 

3

Internal temperature abnormal has occurred and backlight brightness is

 

 

 

 

 

 

dimmed

 

 

 

 

 

4

Temperature sensor abnormal

 

TEMPERATURE ACQUISITION

ERRT

R

 

Value

Returns the temperature of the temperature sensor.

-

 

 

 

 

 

Indicates a temperature sensor abnormality when “126” is returned.

 

 

 

 

 

 

CAUSE OF LAST STANDBY MODE

STCA

W

0

 

Initialization

 

 

 

R

 

0

No detectable error has occurred

 

 

 

 

 

1

Standby mode by POWER button

 

 

 

 

 

2

Main power off by the main power switch

 

 

 

 

3

Standby mode by RS-232C

 

 

 

 

 

 

 

 

 

4

Input signal waiting mode by No Signal

 

 

 

 

 

6

Standby mode by abnormal temperature

 

 

 

 

 

20

Standby mode by OFF IF NO OPERATION setting

 

29 E

Page 29
Image 29
Sharp PN-K321 operation manual 29 E, Others