Mounting Precautions

Mounting Precautions

(For SHARP dealers and service engineers)

When installing, removing or moving the monitor, ensure that this is carried out by at least 2 people.

Be sure to use a wall-mount bracket designed or designated for mounting the monitor.

This monitor is designed to be installed on a concrete wall or pillar. Reinforced work might be necessary for some materials such as plaster / thin plastic board / wood before starting installation.

This monitor and bracket must be installed on a wall which can endure at least 4 times or more the weight of the monitor. Install by the most suitable method for the material and the structure.

To attach a VESA-compliant mounting bracket, use M6 screws that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the thickness of the mounting bracket.

Do not use an impact driver.

When moving the monitor, be sure to hold it with the unit bottom and the side of unit. Do not hold the LCD panel or corners. This may cause product damage, failure, or injury.

Do not use any screw holes other than VESA holes for installation.

nToppling prevention

nToppling prevention Caution

To reduce the risk of injury and damage caused by the product toppling or falling in an earthquake or similar situation, take measures to prevent toppling and falling.

If the wall or platform on which the monitor is installed is not sufficiently strong, the effectiveness of the toppling/ falling prevention measures will be severely compromised. Reinforce the wall or platform as needed.

The toppling/falling prevention measures are intended to reduce the risk of injury and damage in an earthquake, however, the effectiveness of the measures is not guaranteed in all earthquakes.

Before implementing the toppling prevention measures, complete all connections.

Secure to wall or post

1.Attach a commercially available eye bolt (a bolt shaped to allow attachment of a string or cord) to the wall or post.

Verify that the eye bolt is attached firmly and does not come out.

Top of monitor

nRemoving the attachment plate

nRemoving the attachment plate Caution

The attachment plate is only for use with the monitor. Do not use with any other devices.

1.Spread a thick, soft cloth (blanket, etc.) that will prevent damage to the LCD panel on a stable flat surface where the entire monitor can be placed, and place the monitor with the LCD panel face down on the cloth.

2.Remove the screws(x4) that fasten the attachment plate, and remove the attachment plate.

Commercially available eye bolt (bolt shaped to allow attachment of a string or cord)

2.Run a commercially available cord of sufficient strength through the cable clamp attachments and the eye of the eye bolt on the wall or post to secure the monitor.

Top of monitor

Commercially available cord

• Back of monitor