17 E
You can return the settings to their factory-preset values and
restrict operations.
1. After pressing
SIZE
for about 5 seconds, press ,
, , and in that order.
OFF
UNLOCKED
ON
ON
LED
OFF
MONITOR
FUNCTION 1/1
ALL RESET
ADJUSTMENT LOCK
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
CONTROLLER INPUT
END[MENU]
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press , select ALL RESET, and then press
MENU
.
After initialization, turn the main power switch off and
then back on.
When the PN-ZB01 (optional) is attached, press ,
select the resetting method, and then press
MENU
.
ALL RESET1 ....Resets all the settings to the factory
default settings.
ALL RESET2 ....Returns all settings to the factory default
settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT,
ID No. SET, BAUD RATE, NETWORK,
MAIL, SERVICE & SUPPORT, and
SNMP (See page 11, and pages 33 to
36.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
1.........Disables all operations other than turning power
on/off and FUNCTION.
2.........Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not
even power on/off).
RS-232C
(RS-232C/LAN when the PN-ZB01 (optional) is
attached)
Species whether to allow control via RS-232C or LAN
(see pages 18 and 29).
OSD DISPLAY
Hides/shows menus.
The FUNCTION screen cannot be hidden.
LED
Species whether to light the power LED.
OFF cannot be selected when STANDBY MODE is LOW
POWER.
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
TEMPERATURE ALERT
Selects the notication method for an abnormal
temperature.
OFF ..............Do not notify about an abnormal
temperature.
OSD & LED ..When an abnormal temperature is
detected, the power LED ashes in red
and green alternately and the screen
displays a message: TEMPERATURE.
LED...............When an abnormal temperature is
detected, the power LED ashes in red
and green alternately.
STATUS ALERT
Selects the notication method for a hardware error.
OFF ..............Do not notify about the error.
OSD & LED ..When a hardware error is detected, the
power LED ashes in red and the screen
displays a message: STATUS [xxxx].
LED...............When a hardware error is detected, the
power LED ashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
3. Press
MENU
to return to the normal screen.
TIPS
• When both abnormal temperature and hardware error are
detected, the hardware error notication overrides.