![](/images/new-backgrounds/1091424/9142457x1.webp)
2. After adjustment, check the following.
1.In and out play of door remains less than 0.5mm when in the latched position. First check upper position of latch hook, pushing and pulling upper portion of door toward the oven face. Then check lower portion of the latch hook, pushing and pulling lower portion of the door toward the oven face. Both results (play in the door) should be less than 0.5mm.
2.The door sensing switch and secondary interlock switch interrupt the circuit before the door can be opened.
3.Monitor switch contacts close when door is opened.
4.
[14] DOOR REPLACEMENT
1. REMOVAL
1.Disconnect the power supply cord.
2.Open the door slightly.
3.Insert a putty knife (thickness of about 0.5mm) into the gap between the choke cover and corner portion of door panel as shown in Figure
4.Pry the choke cover by inserting a putty knife in order shown in fig- ure
5.Release choke cover from door panel.
6.Now choke cover is free.
NOTE: When carrying out any repair to the door, do not bend or warp the slit choke (tabs on the door panel assembly) to prevent microwave leakage.
8 |
| 9 |
C hoke C over |
| 10 |
|
| |
7 |
|
|
6 |
| 11 |
|
| |
5 |
| 1 |
|
| |
|
| 2 |
4 | 3 | P utty K nife |
|
Door F rame
Figure C-6. Door Disassembly
7.Release two (2) pins of door panel from two (2) holes of upper and lower oven hinges by lifting up.
8.Now, door panel is free from oven cavity.
9.Release door panel from ten (10) tabs of door frame and remove door frame by sliding the door panel downward.
10.Now, door panel with sealer film is free.
11.Tear sealer film from door panel. 12.Now, door panel is free.
13.Slide latch head upward and remove it from door frame with releas- ing latch spring from door frame and latch head.
14.Now, latch head and latch spring are free. 15.Remove door screen from door frame. 16.Now, door screen is free.
R216LS
Door | Latch Hook |
| Door Sensing |
Latch | Switch |
| |
Heads |
|
Monitor Switch
Switch Lever | Secondary |
| |
| Interlock Switch |
| Figure |
17.Unfolded each six (6) tab of the door decoration upper and lower by using a pair of
2. REINSTALL
1.Insert each six (6) tab of the door decoration upper and lower into each slit of the door frame and bend the tabs by using a pair of nee-
2.
3.
4.
5.Put sealer film on door panel. Refer to "Sealer Film" and figure
6.Catch two (2) pins of door panel on two (2) hole of upper and lower oven hinges.
7.
NOTE: After any service to the door;
1)Make sure that door sensing switch, secondary interlock switch and monitor switch are operating properly. (Refer to chapter "Test Procedures".).
2)An approved microwave survey meter should be used to assure compliance with proper microwave radiation emission limitation standards.
3. After any service, make sure of the following :
1.Door latch heads smoothly catch latch hook through latch holes and that latch head goes through center of latch hole.
2.Deviation of door alignment from horizontal line of cavity face plate is to be less than 1.0mm.
3.Door is positioned with its face pressed toward cavity face plate.
4.Check for microwave leakage around door with an approved micro- wave survey meter. (Refer to Microwave Measurement Proce- dure.)