Sharp R-530EK Test Procedures, Letter, Component Test, K Relay Test, L Compu Defrost Test

Models: R-530EK

1 44
Download 44 pages 22.33 Kb
Page 19
Image 19
KRELAY TEST

R - 5 3 0 E K

R - 530EW

TEST PROCEDURES

PROCEDURE

LETTER

COMPONENT TEST

the above method may be used (after clearing the control unit) to determine if the control unit or key pad is at fault.

5.Reconnect all leads removed from components during testing.

6.Re-install the outer case (cabinet).

7.Reconnect the power supply cord after the outer case is installed.

8.Run the oven and check all functions.

LCOMPU DEFROST TEST G 1 Manual backgroundManual background G 2 Manual backgroundManual background G 3 Manual background G 4 Manual backgroundManual background G 5 Manual background G 6 Manual backgroundManual background G 7 Manual background G 8 Manual background

 

 

Beverage

1

 

2

3

4

 

5

 

 

Center

 

 

 

 

 

 

 

 

 

 

 

 

 

Fresh

Rice

From the

6

 

7

8

9

 

0

vegetables

Pantry

 

 

 

 

 

 

 

 

 

 

 

 

Ground

Poultry

 

 

Start

 

Timer

Keep

Snacks

Minute

meat

 

 

Touch On

Clock

Warm

Plus

 

 

 

Plus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vegetables

Fish

 

 

 

Power

 

 

Stop

 

15

Entrees

 

Breakfast

Lunch

 

Minute

Seafood

 

Level

 

Clear

 

 

 

 

 

 

 

Recipes

 

 

 

 

Defrost

Custom

Baked

Sensor

Popcorn

 

 

 

 

Center

Help

potatoes

reheat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual background G 9

Manual background G10

Manual background G11

Manual background G12

Manual background G13

G14

KRELAY TEST

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Disconnect the leads to the primary of the power transformer.

5.Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.

6.After that procedure, re-connect the power supply cord.

7.Remove the outer case and check voltage between Pin No. 1 of the 2 pin connector (A) and the common terminal of the relay RY1 on the control unit with an A.C. voltmeter.

The meter should indicate 120 volts, if not check oven circuit.

RY1 and RY2 Relay Test

These relays are operated by D.C. voltage

Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation. DC. voltage indicated .......................... Defective relay.

DC. voltage not indicated .................... Check diode which is connected to the relay coil. If diode

is good, control unit is defective.

RELAY SYMBOL

OPERATIONAL VOLTAGE

CONNECTED COMPONENTS

 

 

 

RY1

Approx. 24.0V D.C.

Oven lamp / Turntable motor / Cooling fan motor

 

 

 

RY2

Approx. 23.0V D.C.

Power transformer

8.Disconnect the power supply cord, and then remove outer case. 9.Open the door and block it open.

10.Discharge high voltage capacitor.

11.Reconnect all leads removed from components during testing. 12.Re-install the outer case (cabinet).

13.Reconnect the power supply cord after the outer case is installed. 14.Run the oven and check all functions.

LCOMPU DEFROST TEST

WARNING : The oven should be fully assembled before following procedure.

(1)Place one cup of water in the center of the turntable tray in the oven cavity.

(2)Close the door, touch the Defrost Center pad and touch the number pad 5. And touch the number pad 5 again. And then touch the Start pad.

(3)The oven is in Defrost Center cooking condition.

(4)The oven will operate as follows.

17

Page 19
Image 19
Sharp R-530EK service manual Test Procedures, Letter, Component Test, K Relay Test, L Compu Defrost Test