Sharp R-530EK service manual Power Transformer Removal, Magnetron Removal, Reinstallation

Models: R-530EK

1 44
Download 44 pages 22.33 Kb
Page 30
Image 30
POWER TRANSFORMER REMOVAL

R - 5 3 0 E K

R - 530EW

CAUTION: 1. DISCONNECT OVEN FROM POWER SUP PLY BEFORE REMOVING OUTER CASE.

2.DISCHARGE THE HIGH VOLTAGE CA- PACITOR BEFORE TOUCHING ANY OVEN COMPONENTS OR WIRING.

NOTE: When replacing the outer case, the 2 special Torx screws must be reinstalled in the same locations.

Special screw

Screw Driver

(Type: TORX T20 H or GTXH20-100)

POWER TRANSFORMER REMOVAL

1.Disconnect the power supply cord and then remove outer case.

2.Open the oven door and block it open.

3.Discharge high voltage capacitor.

4.Disconnect wire leads (primary and high voltage) from power transformer and the filament leads from the magnetron and capacitor terminals.

5.Remove four (4) screws holding transformer to bottom plate.

6.Remove transformer from bottom plate.

Reinstallation

1.Rest transformer on the bottom plate with its primary terminals toward the oven face plate.

2.Secure transformer with four screws to bottom plate.

3.Re-connect wire leads (primary and high voltage) to power transformer and filament leads of transformer to magnetron and high voltage capacitor. Refer to "PICTORIAL DIAGRAM" on page 35.

4.Re-install outer case and check that oven is operating properly.

HIGH VOLTAGE RECTIFIER AND HIGH VOLTAGE CAPACITOR REMOVAL

1.Disconnect the power supply cord and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Disconnect the high voltage wire A from the high voltage capacitor.

5.Disconnect the high voltage wire of high voltage rectifier assembly from the magnetron.

6.Disconnect the filament lead (short one) of the power transformer from the high voltage capacitor.

7.Remove one (1) screw holding capacitor holder with the high voltage rectifier to the base plate.

8.Disconnect rectifier terminal from capacitor. High voltage rectifier assembly is now free.

9.Remove capacitor holder. Capacitor is now free.

CAUTION: WHEN REPLACING HIGH VOLTAGE RECTI- FIER AND HIGH VOLTAGE CAPACITOR, GROUND SIDE TERMINAL OF THE HIGH VOLTAGE RECTIFIER MUST BE SECURED FIRMLY WITH A GROUNDING SCREW.

MAGNETRON REMOVAL

Removal

1.Disconnect the power supply cord and then remove outer case.

2.Open the door and block it open.

3.Discharge high voltage capacitor.

4.Disconnect wire leads from magnetron.

5.Remove the two (2) screws holding the chassis support to the magnetron and the oven cavity front flange.

6.Slide the magnetron duct slightly so that the two (2) screws at left hand side of the magnetron appear.

7.Carefully remove the four (4) screws holding magnetron to waveguide flange.

8.Remove the magnetron with care so that the magnetron antenna is not hit by any metal object around the antenna.

9.Now, the magnetron is free.

Reinstallation

1.Re-install the magnetron to waveguide flange with care to prevent damage to the magnetron antenna.

2.Secure the magnetron with the four (4) screws.

3.Hold the chassis support to the oven cavity front plate and the magnetron with the two (2) screws.

4.Reconnect the wire leads to the magnetron. Refer to "PICTORIAL DIAGRAM" on page 35.

5.Re-install outer case and check that the oven is operating

properly.

CAUTION: WHEN REPLACING MAGNETRON, BE SURE THE R.F. GASKET IS IN PLACE AND MOUNT- ING SCREWS ARE TIGHTENED SECURELY

28

Page 30
Image 30
Sharp R-530EK Power Transformer Removal, High Voltage Rectifier And High Voltage Capacitor Removal, Magnetron Removal