REINSTALLATION

R - 5 3 0 E K

R - 530EW

13.Now, door panel is free.

14.Slide latch head upward and remove it from door frame by releasing latch spring from door frame and latch head.

15.Now, latch head and latch spring are free. 16.Remove one (1) screw holding the door glass stopper to

the door frame.

17.Remove door glass stopper from door frame.

18.Slide the door glass rightwards and then slide upwards to release the door glass from the tabs holding it.

19.Remove the door glass from the door frame. 20.Now, door frame is free.

REINSTALLATION

1. Re-install door glass to door frame as follows.

1-1. Insert the upper edge of the door glass into the five (5) tabs of the door frame.

1-2. Slide the door glass downwards and insert the lower edge of door glass into the five (5) tabs of the door frame.

1-3. Slide the door glass leftwards and insert the left edge of door glass into the two (2) tabs of the door frame.

2.Re-install the door glass stopper to the door frame so that the two (2) holes of the door glass stopper fit to the two (2) pins of the door frame. And hold the door glass stopper with one (1) screw.

3.Re-install the latch spring to the latch head. Re-install the latch spring to the door frame. Re-install latch head to door frame.

4.Re-install door panel to door frame by catching ten (10) tabs of door frame on the edges of door panel.

5.Put sealer film on door panel. Refer to “Sealer Film” about how to handle new one.

6.Catch two (2) pins of door panel on two (2) hole of upper and lower oven hinges.

7.Re-install choke cover to door panel by pushing.

Note: After any service to the door;

(A)Make sure that door sensing switch and secondary interlock switch are operating properly. (Refer to chapter “Test Procedures”.).

(B)An approved microwave survey meter should be

used to assure compliance with proper microwave radiation emission limitation standards.

After any service, make sure of the following :

1.Door latch heads smoothly catch latch hook through latch holes and that latch head goes through center of latch hole.

2.Deviation of door alignment from horizontal line of cavity face plate is to be less than 1.0mm.

3.Door is positioned with its face pressed toward cavity face plate.

4.Check for microwave leakage around door with an approved microwave survey meter. (Refer to Microwave Measurement Procedure.)

Note: The door on a microwave oven is designed to act as an electronic seal preventing the leakage of microwave energy from oven cavity during cook cycle. This function does not require that door be air- tight, moisture (condensation)-tight or light-tight. Therefore, occasional appearance of moisture, light or sensing of gentle warm air movement around oven door is not abnormal and do not of themselves indicate a leakage of microwave energy from oven cavity.

Pin

 

Upper

Upper Oven

Hinge

Oven Hinge

 

Slit Choke

Lower

Oven Hinge

Lower Oven

Hinge

Pin

Choke Cover

Figure C-5. Door Replacement

SEALER FILM

Installation

1.Put the adhesive tape on the backing film of the sealer film as shown in Fig. C-6.

2.Tear the backing film by pulling the adhesive tape.

3.Put the pasted side of the sealer film on the door panel

Sealer film

Backing film

Adhesive tape

Figure C-6. Sealer film

32

Page 34
Image 34
Sharp R-530EK Sealer Film, Reinstallation, Note After any service to the door, Figure C-5. Door Replacement, Installation