R - 5 3 0 E K
R - 530EW
|
| SPECIFICATION | |
|
|
|
|
ITEM |
|
| DESCRIPTION |
|
| ||
Power Requirements | 120 Volts / 13.8 Amperes | ||
| 60 Hertz |
| |
| Single phase, 3 wire grounded | ||
|
| ||
Power Output | 1200 watts (IEC TEST PROCEDURE) | ||
| Operating frequency of 2450MHz | ||
|
|
|
|
Case Dimensions | Width | 24" |
|
| Height |
| |
| Depth |
| |
|
|
|
|
Cooking Cavity Dimensions | Width |
| |
| Height |
| |
2.0 Cubic Feet | Depth |
| |
|
| ||
Control Complement | Touch Control System | ||
| Clock ( 1:00 - 12:59 ) | ||
| Timer (0 - 99 min. 99 seconds) | ||
| Microwave Power for Variable Cooking | ||
| Repetition Rate; |
| |
| 100 | PERCENT | ............................. Full power throughout the cooking time |
| 90 | PERCENT | ............................................... approx. 90% of Full Power |
| 80 | PERCENT | ............................................... approx. 80% of Full Power |
| 70 | PERCENT | ............................................... approx. 70% of Full Power |
| 60 | PERCENT | ............................................... approx. 60% of Full Power |
| 50 | PERCENT | ............................................... approx. 50% of Full Power |
| 40 | PERCENT | ............................................... approx. 40% of Full Power |
| 30 | PERCENT | .............................................. approx. 30% of Full Power |
| 20 | PERCENT | ............................................... approx. 20% of Full Power |
| 10 | PERCENT | ............................................... approx. 10% of Full Power |
| 0 | PERCENT | .............................. No power throughout the cooking time |
| Sensor Cooking pads, Breakfast pad, Lunch pad | ||
| 15 Minute Recipes pad, Defrost Center pad, From the Pantry pad | ||
| Beverage Center pad, Number selection pads, Timer/Clock pad | ||
| Keep Warm Plus pad, Minute Plus pad, Power Level pad | ||
| Stop/Clear pad, Start/Touch On pad | ||
|
|
|
|
Oven Cavity Light | Yes |
|
|
|
|
| |
Safety Standard | UL Listed | FCC Authorized | |
| DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J | ||
|
|
|
|
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The electrical requirements are a 120 volt 60 Hz, AC only, 15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When installing this appliance, observe all applicable codes and ordinances.
A short
4