RECOMMENDED FRAMING FOR BUILT IN HEATER

RECOMMENDED FRAMING FOR BUILT IN HEATER

When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These type of clearances will make it easy and readily accessible for service.

BUILT IN HEATER CLEARANCES TO COMBUSTIBLES

This unit includes a 3” (75 mm) pedestal and surrounding faceplates. The part of the unit behind the faceplate can be enclosed with combustible material. Model BIH has 1” (25 mm) standoffs to establish clearances to combustibles to the back, top and sides. The minimum clearances and the size of the

enclosure are as follows:

 

 

 

 

-Sides and Rear

I-

0 INCHES

(to standoffs)

-Depth

J- 11 INCHES (275 mm)

-Side wall to unit

-

8

INCHES

(200 mm

Mantle to unit

L-

8

INCHES

(200 mm)