MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI

MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI

The Fireplace Insert model includes surround face plates and a pedestal. When installing this unit, ensure that the pedestal is removed from its box and installed on the bottom of the unit. (Surround assembly instructions are in this manual).

CLEARANCE TO COMBUSTIBLES:

 

 

Side wall

8” (200 mm) from the body of the heater

Facing on masonry fireplace

8” (200 mm) from the body of the heater

Mantle

8” (200 mm) from the body of the heater

FIREPLACE INSERT SIZE:

 

 

Width

22”

(550 mm)

Height

22 ¾”

(570 mm)

Depth

24”

(600 mm)

A noncombustible hearth pad must cover combustible flooring underneath, as well as 6” (150 mm) in front of the heater and 6” (150 mm) to the side of the heater

1.Install the hearth pad

2.Lock fireplace damper in the open position

3.Install positive flue connector at the fireplace dampers.

4.Connect a tee or 90-° degree elbow to the exhaust pipe

5.This fireplace insert must be installed with a continuous chimney liner of 3 or 4” diameter extending from the fireplace insert to the top of the chimney. The liner must conform to type 3 requirements of CAN/ULC S635.

6.(Recommended) Install fresh air intake either through the

back of the fireplace or through the positive flue connector..

When installing the insert into a masonry fireplace DO NOT remove any bricks or masonry, with the following exception; Masonry or steel, including the damper plate, may be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner. Provided that their removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for combustible materials to less than that required by the national building code.

When installing the fireplace insert into a zero clearance fireplace, DO NOT cut or modify any factory firebox parts. If the fireplace insert does not fit into a zero clearance fireplace we recommend you use an ENVIROFIRE model FS and

install as a hearth mounted unit. Install a 3” (76 mm) flex pipe from the stove to the top of the chimney.