DO NOT:

-Hold the start-up switch down, this is a momentary contact switch and can be damaged if held down too long.

-Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures.

-Remove any screws in the firebox without first lubricating them with penetrating oil.

TROUBLESHOOTING:

What to do if:

1.The stove will not start

2.The stove will not operate when hot

3.The exhaust blower will not function

4.The convection blower will not function normally

5.Igniter , The pellets will not light.

6.The auger motor does not function normally

7.The Dial-A-Fire has no effect on the fire

8.The stove will not shut off

9.The stove keeps going out

*NOTE: All troubleshooting procedures should be carried out by qualified technicians.

1.The stove will not start

-Make sure the stove is plugged in and the wall outlet is supplying power.

-Push the Start-up switch, if the stove fails to start, unplug the unit and open the hinged side panels (held tight with two screws).

-With the stove unplugged, examine all connections. Make sure they are firmly connected and that there are no exposed wires touching the stove (except the chassis ground wire).

-Check the continuity and placement of connections against the diagram in the back of this manual.

-Ensure that the connections to the (15) minute start-up timer are correct.

-Attempt to bypass the switch by inserting a jumper wire between the red and white wires that attach to the switch. Plug the stove back in. If the stove starts, replace the switch.

-If this fails, replace the (15) minute start-up timer.

2.The stove will not operate when hot

-Unplug the stove, open the left side panel. Jump the two brown leads that are attached to the 140°F (60°C) temperature sensor. If the stove operates replace the 140°F (60°C) sensor.

3.The exhaust motor will not function normally

-Open the left side panel, check all connections against the wiring diagram.

-If all the connections are verified and the exhaust blower does not function at all, tap lightly on the exhaust blower’s motor end cap, this may loosen a tight motor.

-Apply 230V AC directly to the exhaust blower. If the motor does not run, replace the blower.

-If the motor runs, have your dealer check the harness.