Real Applications

International English

7.3.3Key Parameter Details

Note.

Careful selection of the inputs is needed to ensure the correct combination of forward and reverse frequencies is possible.

Table 7-3 Key Parameters. Lift Door Operation

Number

Value

Meaning

 

 

 

P1000

3

Fixed Frequencies selected

 

 

 

P0003

3

Allows all parameters to be adjusted and set

 

 

 

P1001

- 5

Fixed Frequency 1. Setting the following parameters allows the complex

 

 

selection of fixed frequencies, forward and reverse, to be selected using

 

 

only the two microswitch inputs and the open/close signal

 

 

 

P1002

-6

Fixed Frequency 2

 

 

 

P1003

- 15

Fixed Frequency 3

 

 

 

P1004

5

Fixed Frequency 4

 

 

 

P1005

+25

Fixed Frequency 5

 

 

 

P1006

+2

Fixed Frequency 6

 

 

 

P1007

+10

Fixed Frequency 7

 

 

 

P0701-3

17

Binary selection of fixed frequencies

 

 

 

P0300-

***

Settings to suit motor

P0311

 

 

 

 

 

40

MICROMASTER Applications Handbook