7.5.4Key Parameter settings
Table
Number | Value | Meaning |
|
|
|
P1120 | 0.3 | Ramp up |
|
|
|
P1121 | 0.3 | Ramp down |
|
|
|
P0003 | 003 | Allows all parameters to be adjusted and set. |
|
|
|
P1082 | 100 | Maximum Output Frequency. This wide speed range is possible |
|
| because torque requirements are not excessive at high speed. |
|
|
|
P2000 | 100 | Reference Frequency. Used for analog, serial I/O etc. |
|
| corresponds to |
|
|
|
P0701 | 2 | Run left |
|
|
|
P0702 | 1 | Run right |
|
|
|
P0703 | 29 | External Trip |
|
|
|
P0731 | 52.3 | Output Relay 1 Brake control. Here the brake control operates |
|
| immediately as P1216 and P1217 are set to 0. |
|
|
|
P1215 | 1 | Enable brake control function |
|
|
|
P1216 | 0 | Brake release time |
|
|
|
P1217 | 0 | Brake stop time |
|
|
|
P1310 | 0 | Continuous boost. In this application starting boost (P1312) proved |
|
| more useful than continuous boost. |
|
|
|
P1312 | 100 | Starting boost |
|
|
|
P0300- | *** | Settings to suit motor |
P0311 |
|
|
|
|
|
44 | MICROMASTER Applications Handbook |