7.5.4Key Parameter settings

Table 7-5 Key Parameters. Material Handling Operation

Number

Value

Meaning

 

 

 

P1120

0.3

Ramp up

 

 

 

P1121

0.3

Ramp down

 

 

 

P0003

003

Allows all parameters to be adjusted and set.

 

 

 

P1082

100

Maximum Output Frequency. This wide speed range is possible

 

 

because torque requirements are not excessive at high speed.

 

 

 

P2000

100

Reference Frequency. Used for analog, serial I/O etc. 0-10 V now

 

 

corresponds to 0-100 Hz

 

 

 

P0701

2

Run left

 

 

 

P0702

1

Run right

 

 

 

P0703

29

External Trip

 

 

 

P0731

52.3

Output Relay 1 Brake control. Here the brake control operates

 

 

immediately as P1216 and P1217 are set to 0.

 

 

 

P1215

1

Enable brake control function

 

 

 

P1216

0

Brake release time

 

 

 

P1217

0

Brake stop time

 

 

 

P1310

0

Continuous boost. In this application starting boost (P1312) proved

 

 

more useful than continuous boost.

 

 

 

P1312

100

Starting boost

 

 

 

P0300-

***

Settings to suit motor

P0311

 

 

 

 

 

44