Configuring network settings

 

 

Gateway (Next Hop)

Enter the gateway IP address in this box. The gateway is the

 

computer in the network, which establishes the connection between

 

different network segments. If the device is only to be accessed by

 

other devices in the same network segment, enter 0.0.0.0 here.

MAC-Address

Displays the network card ID.

Link Speed

Choose the speed from the list. Automatic is the preferred setting.

10.1Changing the device IP address

There are two ways of changing the device IP address: Changing the device IP address via the device homepage. Changing the IP address using the Web-Cam IP Manager

If the current IP address setting is not known, communication with the device can be re-established in the service mode. See section 18: Service mode.

9.1.1.Changing the device IP address via the device homepage.

There are two methods of allocating a new IP address to the device using the device homepage:

Automatic address designation by the DHCP or BOOTP server By allocating an IP address manually

Automatic address designation by the DHCP or BOOTP server

1.Call up the device homepage. See section 9.1: Calling up the device homepage.

2.Select Network settings in the Configuration menu. The Network settings dialogue window opens:

3.Activate the Automatic network configuration (DHCP) check box

Each time the device is restarted, the DHCP or BOOTP server will automatically reinstate the network settings (IP address, subnet mask and gateway, if applicable).

4.Restart your IP-Module. See section 14: Restarting the IP Module.

Manual IP address and subnet mask allocation

1.Call up the device homepage. See section 9.1: Calling up the device homepage.

2.Select Network settings in the Configuration menu. The Network settings dialogue window opens:

3.Enter the device IP address in the IP-Addressbox.

The IP address is made up of four numbers in the range 0 - 255, which are separated from each other by decimal points. The IP address must be compatible with an existing network and a given address may only be allocated to one device. In the case of new networks, which do not use the official internet address space, we recommend you use the ranges 192.168.x.x and 10.x.x.x. Each x represents a number in the range 0 to 255. If the device is to be connected directly to internet, you must use an officially registered IP address, which will be notified to you by your internet service provider. See section 16: Establishing access to the device via internet.

4.Enter the device subnet mask in the Subnet Mask box.

21

Siemens Building Technologies

Fire Safety & Security Products

Page 21
Image 21
Siemens CFVA-IP user manual Changing the device IP address, Automatic address designation by the Dhcp or Bootp server

CFVA-IP specifications

Siemens CFVA-IP is an advanced control system designed for industrial automation, combining performance, flexibility, and reliability to meet the diverse demands of modern manufacturing processes. This system is engineered to operate seamlessly across various industries, including automotive, food and beverage, and pharmaceuticals.

One of the primary features of the CFVA-IP is its integration capability with existing infrastructure. It supports a wide array of communication protocols, allowing for easy connection with legacy systems and new components alike. This ensures a smooth transition and interoperability within the industrial ecosystem, reducing downtime and enhancing productivity.

The CFVA-IP utilizes state-of-the-art technologies, such as Ethernet and IP-based communication, to facilitate high-speed data transfer and real-time control. This enables operators to monitor processes and make informed decisions quickly. The system is equipped with advanced diagnostic tools that provide insights into operational performance, helping to identify potential issues before they escalate into significant problems.

A notable characteristic of the Siemens CFVA-IP is its modular design. This allows for easy customization and scalability, enabling manufacturers to expand their systems as needed without significant overhauls. Users can select from various input/output modules, communication interfaces, and power supplies to tailor the system to their specific applications and requirements.

Additionally, the CFVA-IP features comprehensive safety measures, including built-in redundancy and support for safety protocols. It complies with international safety standards, ensuring that operations can continue securely even in critical scenarios. This feature is particularly essential in industries where safety and regulatory compliance are paramount.

Another significant advantage of the Siemens CFVA-IP is its user-friendly interface. The system includes intuitive software tools designed to ease programming and control. The graphical interface simplifies configuration and monitoring, allowing even less technically inclined users to operate the system efficiently. Moreover, training tools and extensive documentation are available, ensuring that staff can quickly adapt to the new system.

In conclusion, Siemens CFVA-IP stands out as a versatile and robust solution for industrial automation. Its combination of integration capability, advanced technologies, modular design, safety features, and user-friendly interface makes it an ideal choice for companies looking to modernize their manufacturing processes while maintaining efficiency and reliability. The CFVA-IP not only meets current automation needs but is also poised to adapt to future challenges in the ever-evolving industrial landscape.