5 Technical data

Technical data

5 Technical data

5.1Technical data for IP-Module CFVA-IP

Electrical supply

12 V DC/24 V AC

Power requirement

max. 6.0 W

Operating temperature range

-10 – +45 °C, max. relative humidity 90%

Storage temperature range

-20 – +60 °C

Dimensions (H x Ø)

35.5 x 140 mm

Weight

400 g

Material

Aluminum

System requirements

All systems, which feature TCP/IP network functions and

 

provide an http browser (Microsoft Internet Explorer from

 

version 5.5 with Java plug-in or Mozilla or Netscape from

 

version 7.0).

Protocols

ARP, BOOTP/DHCP, TCP/IP, HTTP, ICMP, SNMP, FTP

 

and DNS

Installation

IP address configurable via ARP, BOOTP/DHCP,

 

connection to twisted-pair RJ45 Ethernet.

Network connection

10BaseT Ethernet or 100BaseTX Fast Ethernet, auto-

 

sensing, full/half duplex

Image formats

QCIF (176x144),

 

CIF (352x288),

 

4CIF (704x576) (interlaced).

Image transmission

Motion JPEG (multipart/x-mixed-replace content type),

 

user configurable JPEG single image frame quality,

 

streaming up to 25 images per second with QCIF and

 

CIF or up to 10 images per second with 4CIF.

Security

Separate passwords for image access and system

 

configuration.

Hardware

8 MB RAM, 16 MB flash ROM