Illue 5, June 1999

If, during initial setup of the Optiset terminal, a line was configured for Autoanswer, then incoming calls on that line are connected automatically. Depending on how the line was configured, either no alerting or a single ring will occur for an incoming call.

Autoanswer Key

If no Optiset terminal lines were set up for Autoanswer. the Autoanswer key can be used to initiate this feature. While this feature is active. all incoming calls are answered automatically without any action required by the user. Depending on how the Line key ringing option was configured, and incoming call may be accompanied either by no alerting or by a single ring.

Reject a Call (No Other Calls Active)

Reject (Menu and Dialog Keys)

If the calling-party information in the display indicates that the incoming call is one you do not want to receive, use the dialog keys to select the Reject Call option from the menu system. Call alerting (ringing and status-light flashing) ceases.

Disconnect (Key)

To reject an incoming alerting call, press the Disconnect key. Alerting ceases immediately.

Reject a Call (With Another Call Active)

Reject (Menu and Dialog Keys)

If, during an active call, alerting begins for another incoming call, the menu system briefly displays the Incoming Call Ringing menu. To reject the incoming alerting call, select the

Reject Call option from the menu. Alerting ceases immediately.

Disconnect (Key)

If, during an active call, alerting begins for another incoming call, the menu system briefly displays the Incoming Call Ringing menu. While this menu is being displayed, you can

30

1275·00030

Issue 5, June 1999

reject the alerting call by pressing the Disconnect key. Alerting ceases immediately.

Note that if you press the Disconnect key after the Incoming Call Ringing menu is no longer displayed, the existing active call is disconnected!

Preview (Key)/line Key/Reject (Menu and Dialog Keys) or Disconnect (Key)

To reject an alerting incoming call that occurs while you have another call active, you can press the Preview key to place the terminal in the preview mode; then press the line key associated with the alerting incoming call; finally, use the menu system to select the Reject Call option, or press the Disconnect key. Alerting ceases immediately.

Reject All Calls (Do Not Disturb)

Do Not Disturb (Key)

While no incoming calls are alerting, press the Do Not Disturb key. The indicator next to the Do Not Disturb key lights. All future incoming calls are automatically rejected, and no alerting occurs, until the Do Not Disturb feature is turned off.

Clear an Active/Connected Call

On-hook (Handset)

Place the handset back in the cradle to clear an active, connected call.

On-hook (Speaker Key)

If the microphone and speaker are being used, press the Speaker key to clear an active, connected call.

Disconnect (Key or Menu and Dialog Keys)

Select the Disconnect Call option from the menu system or press the Disconnect key to clear an active, connected call. If the handset is in use, it becomes idle until either the cradle switch is pressed and released, a call on hold is retrieved, or a

1275·00030

31

Page 21
Image 21
Siemens NI-1200 specifications Illue 5, June

NI-1200 specifications

The Siemens NI-1200 is a versatile and innovative device designed for a wide range of automation and control applications. As part of Siemens' extensive portfolio, the NI-1200 showcases cutting-edge technologies and features that enhance operational efficiency and flexibility in industrial environments.

One of the main features of the NI-1200 is its robust processing power. With a high-performance processor, the device is capable of handling complex automation tasks in real-time. This enables seamless integration with various automation components, allowing for greater control and monitoring of processes.

The NI-1200 is equipped with advanced communication capabilities, supporting various industrial communication protocols such as Ethernet/IP, Profinet, and Modbus. This extensive connectivity makes it easy for the device to interface with other systems, sensors, and actuators, promoting interoperability and data exchange across different platforms.

In terms of data handling, the NI-1200 offers rich data logging and analysis features. Users can collect, store, and analyze data from different sources, which is essential for process optimization and troubleshooting. This capability ensures that organizations can make informed decisions based on accurate and timely data, ultimately leading to improved productivity and reduced downtime.

The device is also designed with scalability in mind. Whether organizations are looking to implement a small-scale solution or require extensive systems integration, the NI-1200 can adapt to changing needs. Its modular design allows for easy upgrades and expansions, catering to future growth and evolving technology landscapes.

Another key characteristic of the Siemens NI-1200 is its user-friendly interface. The device features an intuitive graphical user interface (GUI) that simplifies configuration and monitoring tasks. This ease of use reduces the learning curve for operators and maintenance personnel, enhancing overall productivity.

Additionally, the NI-1200 is built with durability and reliability in mind, suitable for harsh industrial environments. It complies with international standards for safety and environmental conditions, making it a dependable choice for various applications, including manufacturing, process control, and building automation.

In summary, the Siemens NI-1200 is a powerful and feature-rich automation device that stands out for its processing capabilities, communication options, scalability, and user-friendly interface. Its combination of advanced technologies and robust characteristics makes it an ideal solution for organizations looking to enhance their automation and control processes. With the Siemens NI-1200, businesses can achieve greater efficiency, flexibility, and reliability in their operations.