Configuring Communication Connections
130 SIMATIC NET NCM S7 for Industrial Ethernet
C79000-G8976-C129–06
Attributes Description Access
Local Endpoint
ID The entry is identical to the Local ID parameter in the
connection list. Selectable
Name When you create the connection, a name is proposed here
along with a connection number as suffix.
With unspecified connections, use this box to identify the
partner.
Modifiable
Via CP If the station contains more than one CP of the same type
connected to the same subnet, you can select the connection
route –> “Route”, see Section 4.8.
If no CP is assigned (for example because the CP has been
deleted) “none” is displayed here.
Display only
Block Parameters
ID This value must be entered as a block call parameter ID for
calling the FC in the user program to identify the connection.
The ID changes if the local ID is changed.
Display only
LADDR This value must be entered as a block call parameter ID for
calling the FC in the user program to identify the connection. Display only
Connection Name (Reference) – Only in Multiproject
If you create a connection to a partner in another project, that has not yet been
merged with the current multiproject, you must enter a connection name as
reference. Interproject connections can then be joined up based on this reference.
As soon as the connections have been brought together, the connection name
(reference) can no longer be entered.