Siemens PCS7, TM manual General Information About the Installation, Content of the CD

Models: PCS7 TM

1 21
Download 21 pages 10.11 Kb
Page 5
Image 5

These blocks can be installed on demand by checking the component “Standard-OCX renoviert” in the installation program.

2.4PCS7/TM-OCX (PCS7) (formerly: WinCC/TM-OCX (PCS7))

2.4.1Modifications vs. Version V2.01

None.

3 General Information About the Installation

Requirements

The software products that are contained on this CD are released under WinCC, Version 5.0/SP2+ HF7, or PCS7, Version 5.2, and Windows NT, 4.0 + SP5. The hardware requirements are listed in the associated documents (Vertriebsfreigabe zu PCS7/TM, V2.02, in TELEPERM M aktuell).

With transition to PCS7, V5.2, the C partition of the used computer must have a memory of at least 4 GByte.

Please observe the Chapter 5 “Version Interdependencies” in this document.

3.1Operation system Windows NT, 4.0, Upgrading to SP5

Note: The PCS 7/TM CD does not contain the operation system Windows NT, 4.0, or any Service Packs (SP).

Language variants of the SP must be used according to the selection in the base installation.

To install the NT SP5, load the corresponding Setup.exe. Overwrite older files when the system asks for file versions during the installation process. Please observe the notes etc. of the SP5.

3.2Content of the CD

The software components for PCS 7/TM and the documents are supplied on CD-ROM. CD directory structure under the directory PCS7_Version_5 (excerpt):

-Dok

-Siemens

-SW

-Winnt.400

Contains the product information and all the descriptions in pdf format (see chapter 4)

Contains the channel components in an uncompressed form, 2 example projects as well as a part of a project and some Scripts and functions

Contains the installation programs for channel and image blocks (and additional products)

Contains the old driver software for the N_AT module

3.3Installation using the Common Installation Mask

This CD is equipped with an “Autorun” facility that automatically starts the installation mask when the CD is inserted (provided that the computer has been set up for this feature). If this selection has not been made in your computer, the installation mask can also be initiated by double-clicking on the setup.exe in the CD’s root directory.

Using the common installation mask it is sufficient to select all components to be installed. When WinCC/TM is selected, the check is automatically set for the NAT-NPCIdriver software. The check can be removed if this driver software shall not be installed. The language selection in the in-

Product Information

PCS7/TM V2.02

24.10.2001

© Siemens AG 2001

5 of 21

 

Page 5
Image 5
Siemens General Information About the Installation, PCS7/TM-OCX PCS7 formerly WinCC/TM-OCX PCS7, Content of the CD