3.6Installation of the PCS7/TM-OCX (PCS7) (formerly: WinCC/TM-OCX (PCS7))

The image blocks in a PCS7-similar representation and the authorization DLL that is necessary for proper operation are located in the directory sw\OCX_TM7 on the CD.

The authorization is supplied on a separate floppy disk.

This package must be installed in all computers that shall be used for operator communication and visualization:

-Single-user system, also ES

-Multi-clients or Clients

-Server, if the server is operator station at the same time.

3.6.1Procedure of the manual installation

There is an older version of WinCC /TM-OCXen (PCS7) in your computer and the objects WinCC/TM-OCX (PCS7) and VB5_DLL are contained in the "Settings/System con- trol/Software" tab:

Uninstall these two objects.

To install the image blocks in PCS7-similar representation branch to the SW\ OCX_TM7 di- rectory and invoke Setup.exe there. The further install procedure will be prompted. Also install the VB6_DLL (in the same setup).

Any existing installation will be removed during this process.

The "Prototype images" option can be used for copying these images into the corresponding WinCC folder from where they will be copied into the project when the Split Screen Wizard executes.

The authorization must be transferred to the same drive as the other PCS7 authorizations. To do this, please insert the authorization floppy disk into the drive and double-click on the Authors.exe or Authorsw.exe program (same procedure as for other PCS7/ WinCC compo- nents).

Of course, this step is only necessary if an authorization has not yet been installed.

The image blocks in PCS7-similar representation are now ready for the configuration in the WinCC- Graphics Designer.

Note: Some image blocks in PCS7-similar representation need more parameters in the ORPA filter than the ones in TELEPERM M representation. Instead of the ORPAFilter.txt file that was copied into the <LW>:\Siemens\WinCC\BSTMapper directory during the installation of the TELEPERM M channel, ORPAFilter from the TM7 directory of the CD shall therefore be used. This directory also contains the prototype images.

3.6.2Revision levels

ElementeTM7.ocx

V3.00.00

Input.ocx

V3.00.00

TM7_x

V3.00.00

3.6.3What to do after the installation ?

After the successful installation all optionally installed prototype images may be copied with the WinCC-Split Screen Wizard into the current project.