Product Information PCS7/TM V2.02 24.10.2001
Siemens AG 2001 7 of 21
3.4 Installation of the TELEPERM M Channel DLL and Tools
The TELEPERM M channel-DLL and tools package must be installed in the following WinCC comput-
ers: - Single-user system, also ES
- Client/ server system: in all servers, in the clients merely the TELE PERM M.chn channel and
all files of the Telpm*.lng. type.
- Multi-client system: in all servers, in the multi-clients merel y the TELEPERM M.chn channel
and all files of the Telpm*.lng type.
The authorisation is supplied on a separate floppy disk.
Manual installation:
To install the TELEPERM M channel DLL and tools, please branch to th e SW\ Kanal directory and
invoke Setup.exe there. From now on, the installation procedure will be prompted. The default setting
of <LW> is the installation drive of WinCC. This setting must not be cha nged.
If not already done explicitly at the beginning any existing installation will be removed during this proc-
ess.
If it does not yet exist, the authorization must be transferred to the PCS 7 i nstallation drive. To
do this, please insert the authorization floppy disk into the drive and double-click on the
Authors.exe or Authorsw.exe program (same procedure as for other PCS 7 components).
The installation is thus performed. Further information can be found in t he
<LW>:\Siemens\TM_Werkzeuge\Liesmich.txt
file or in the documentation.
The files Ydata220.dat and Ydata230.dat that are included in the deliver y contain the data that
is relevant for the W startup, and must not be modified.
Depending on the installed authorization, this software version perm its communication with the
following automation systems:
- AS 230/ AS 235/ AS 235H/ AS 388/ AS 488
AS 215
AG 150U / AG 155U
- AS 220S/ AS 220H
(See also Chapter 3.7 "Necessary Licenses")
Startup features:
The AS systems are marked as failed during the entire duration of the startup phase.
Furthermore, all AS systems must be operational on the bus at the startup time.
3.4.1 Installation of the N_AT/N_PCI driver
If the N_AT driver is required, it can be installed via a separate insta llation procedure (NAT-NPCI).
Please execute the program Setup.exe in the directory sw\NAT_NPCI.
3.4.2 What to do after the Installation ?
After the successful installation all delivered TM configuration tools, i.e. wizards, should be imported
with the WinCC-Dynamic Wizard Editor.
This is not necessary if the Split Screen Wizard is executed (recomm endation); herewith the current
TM configuration tools are copied into the project and are available ther e.